Loading…
Experimental determination of convective heat transfer coefficient during controlled frying of potato discs
The convective heat transfer coefficient was measured experimentally using a controlled one-dimensional (1-D) frying methodology. Hollow Teflon disc was used as a sample holder. Thermostable silicon glue was used to seal the sample in the Teflon disc. This insulated the edges of the potato disc from...
Saved in:
Published in: | Food science & technology 2016-01, Vol.65, p.180-184 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The convective heat transfer coefficient was measured experimentally using a controlled one-dimensional (1-D) frying methodology. Hollow Teflon disc was used as a sample holder. Thermostable silicon glue was used to seal the sample in the Teflon disc. This insulated the edges of the potato disc from the frying oil thus restricting oil penetration from only the exposed top and bottom surfaces. This rendered this set of frying experiments a 1-D frying process. The peak heat transfer coefficient values were determined to be 3617, 4517 and 7307 W/m2 °C at frying temperatures of 150, 170 and 190 °C, respectively. The heat transfer coefficient reached its peak value towards the end of frying at all temperatures.
•Frying experiments with time-varying oil temperature were performed.•Frying was performed on a weighing scale to measure rate of evaporation.•Measured h values were higher than previously reported in literature. |
---|---|
ISSN: | 0023-6438 1096-1127 |
DOI: | 10.1016/j.lwt.2015.08.007 |