Loading…
Study of Signal to Noise Ratio of Coded Source Neutron Imaging with Analysis Method and Numerical Simulation
Coded source imaging (CSI) technique could increase the utilization rate of neutron when high L/D required in neutron imaging. The images need to be reconstructed from the raw projections. The reconstruction would amplify the noise of the raw projection, which will affect the quality of reconstructe...
Saved in:
Published in: | Physics procedia 2017, Vol.88, p.340-347 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Coded source imaging (CSI) technique could increase the utilization rate of neutron when high L/D required in neutron imaging. The images need to be reconstructed from the raw projections. The reconstruction would amplify the noise of the raw projection, which will affect the quality of reconstructed images. Study of Signal to Noise Ratio (SNR) in CSI shows image quality depends on geometry structure and neutron beam parameters. With analysis method based on correlation reconstruction arithmetic, SNR was detailed to assess the effects from different geometry factors. Numerical simulation as a further supplement proves the rationality of analysis method. The comparison of SNR between CSI and traditional neutron radiography (NR) shows that the SNR of CSI could be better than NR in some conditions. |
---|---|
ISSN: | 1875-3892 1875-3892 |
DOI: | 10.1016/j.phpro.2017.06.046 |