Loading…

Development of a Method to Evaluate the Release Profile of Tamoxifen from Pegylated Hybrid Micelles

Studies of in vitro release profiles are important during the development of drug delivery systems. This article describes the development and validation of a RP-HPLC method for the quantification of drug released from tamoxifen-loaded DSPE-PEG(2000)/TPGS micelles and the determination of the best d...

Full description

Saved in:
Bibliographic Details
Published in:Journal of liquid chromatography & related technologies 2015-07, Vol.38 (12), p.1223-1229
Main Authors: Claro de Souza, Marina, Marotta-Oliveira, Samantha Sant'Anna, Rocha, Nathália Helena Souza, Eloy, Josimar O., Marchetti, Juliana Maldonado
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c338t-4bace8bd7e0693035f844dc32fe9ceb241073d4e36333eec5b99281a0ca2ca393
cites cdi_FETCH-LOGICAL-c338t-4bace8bd7e0693035f844dc32fe9ceb241073d4e36333eec5b99281a0ca2ca393
container_end_page 1229
container_issue 12
container_start_page 1223
container_title Journal of liquid chromatography & related technologies
container_volume 38
creator Claro de Souza, Marina
Marotta-Oliveira, Samantha Sant'Anna
Rocha, Nathália Helena Souza
Eloy, Josimar O.
Marchetti, Juliana Maldonado
description Studies of in vitro release profiles are important during the development of drug delivery systems. This article describes the development and validation of a RP-HPLC method for the quantification of drug released from tamoxifen-loaded DSPE-PEG(2000)/TPGS micelles and the determination of the best dissolution medium and apparatus for this assay. The method showed specificity, linearity, precision, accuracy, and robustness for the parameters evaluated (range 0.25-20.0 µg mL −1 ). The best dissolution medium was 1.0 mol L −1 sodium salicylate, pH 7.4, and the most suitable apparatus was a PVC tube with one end covered with a dialysis membrane. This method was shown to be useful for tamoxifen quantification in in vitro release studies.
doi_str_mv 10.1080/10826076.2015.1032418
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1080_10826076_2015_1032418</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3707572091</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-4bace8bd7e0693035f844dc32fe9ceb241073d4e36333eec5b99281a0ca2ca393</originalsourceid><addsrcrecordid>eNp9kFtLAzEQhRdRsFZ_ghDweWsum728KbVaoWKRCr6FbHZit2Q3NdlW99-bpfXVl5lh-M4Z5kTRNcETgnN8GwpNcZZOKCY8rBhNSH4SjQinOOYZ_TgNc2DiATqPLrzfYEwyTvkoUg-wB2O3DbQdshpJ9ALd2laos2i2l2YnO0DdGtAbGJAe0NJZXRsY2JVs7E-toUXa2QYt4bM3Aa_QvC9dXaGXWoEx4C-jMy2Nh6tjH0fvj7PVdB4vXp-ep_eLWDGWd3FSSgV5WWWA04JhxnWeJJViVEOhoAxP4YxVCbCUMQageFkUNCcSK0mVZAUbRzcH362zXzvwndjYnWvDSUHSPE0SznIWKH6glLPeO9Bi6-pGul4QLIY8xV-eYshTHPMMuruDrm61dY38ts5UopO9sU472araC_a_xS8RxXxf</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1686445383</pqid></control><display><type>article</type><title>Development of a Method to Evaluate the Release Profile of Tamoxifen from Pegylated Hybrid Micelles</title><source>Taylor and Francis Science and Technology Collection</source><creator>Claro de Souza, Marina ; Marotta-Oliveira, Samantha Sant'Anna ; Rocha, Nathália Helena Souza ; Eloy, Josimar O. ; Marchetti, Juliana Maldonado</creator><creatorcontrib>Claro de Souza, Marina ; Marotta-Oliveira, Samantha Sant'Anna ; Rocha, Nathália Helena Souza ; Eloy, Josimar O. ; Marchetti, Juliana Maldonado</creatorcontrib><description>Studies of in vitro release profiles are important during the development of drug delivery systems. This article describes the development and validation of a RP-HPLC method for the quantification of drug released from tamoxifen-loaded DSPE-PEG(2000)/TPGS micelles and the determination of the best dissolution medium and apparatus for this assay. The method showed specificity, linearity, precision, accuracy, and robustness for the parameters evaluated (range 0.25-20.0 µg mL −1 ). The best dissolution medium was 1.0 mol L −1 sodium salicylate, pH 7.4, and the most suitable apparatus was a PVC tube with one end covered with a dialysis membrane. This method was shown to be useful for tamoxifen quantification in in vitro release studies.</description><identifier>ISSN: 1082-6076</identifier><identifier>EISSN: 1520-572X</identifier><identifier>DOI: 10.1080/10826076.2015.1032418</identifier><language>eng</language><publisher>Abingdon: Taylor &amp; Francis</publisher><subject>analytical development and validation ; drug delivery systems ; hybrid pegylated micelles ; in vitro release profile ; RP-HPLC quantification ; tamoxifen</subject><ispartof>Journal of liquid chromatography &amp; related technologies, 2015-07, Vol.38 (12), p.1223-1229</ispartof><rights>Copyright © Taylor &amp; Francis Group, LLC 2015</rights><rights>Copyright © Taylor &amp; Francis Group, LLC</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-4bace8bd7e0693035f844dc32fe9ceb241073d4e36333eec5b99281a0ca2ca393</citedby><cites>FETCH-LOGICAL-c338t-4bace8bd7e0693035f844dc32fe9ceb241073d4e36333eec5b99281a0ca2ca393</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Claro de Souza, Marina</creatorcontrib><creatorcontrib>Marotta-Oliveira, Samantha Sant'Anna</creatorcontrib><creatorcontrib>Rocha, Nathália Helena Souza</creatorcontrib><creatorcontrib>Eloy, Josimar O.</creatorcontrib><creatorcontrib>Marchetti, Juliana Maldonado</creatorcontrib><title>Development of a Method to Evaluate the Release Profile of Tamoxifen from Pegylated Hybrid Micelles</title><title>Journal of liquid chromatography &amp; related technologies</title><description>Studies of in vitro release profiles are important during the development of drug delivery systems. This article describes the development and validation of a RP-HPLC method for the quantification of drug released from tamoxifen-loaded DSPE-PEG(2000)/TPGS micelles and the determination of the best dissolution medium and apparatus for this assay. The method showed specificity, linearity, precision, accuracy, and robustness for the parameters evaluated (range 0.25-20.0 µg mL −1 ). The best dissolution medium was 1.0 mol L −1 sodium salicylate, pH 7.4, and the most suitable apparatus was a PVC tube with one end covered with a dialysis membrane. This method was shown to be useful for tamoxifen quantification in in vitro release studies.</description><subject>analytical development and validation</subject><subject>drug delivery systems</subject><subject>hybrid pegylated micelles</subject><subject>in vitro release profile</subject><subject>RP-HPLC quantification</subject><subject>tamoxifen</subject><issn>1082-6076</issn><issn>1520-572X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNp9kFtLAzEQhRdRsFZ_ghDweWsum728KbVaoWKRCr6FbHZit2Q3NdlW99-bpfXVl5lh-M4Z5kTRNcETgnN8GwpNcZZOKCY8rBhNSH4SjQinOOYZ_TgNc2DiATqPLrzfYEwyTvkoUg-wB2O3DbQdshpJ9ALd2laos2i2l2YnO0DdGtAbGJAe0NJZXRsY2JVs7E-toUXa2QYt4bM3Aa_QvC9dXaGXWoEx4C-jMy2Nh6tjH0fvj7PVdB4vXp-ep_eLWDGWd3FSSgV5WWWA04JhxnWeJJViVEOhoAxP4YxVCbCUMQageFkUNCcSK0mVZAUbRzcH362zXzvwndjYnWvDSUHSPE0SznIWKH6glLPeO9Bi6-pGul4QLIY8xV-eYshTHPMMuruDrm61dY38ts5UopO9sU472araC_a_xS8RxXxf</recordid><startdate>20150721</startdate><enddate>20150721</enddate><creator>Claro de Souza, Marina</creator><creator>Marotta-Oliveira, Samantha Sant'Anna</creator><creator>Rocha, Nathália Helena Souza</creator><creator>Eloy, Josimar O.</creator><creator>Marchetti, Juliana Maldonado</creator><general>Taylor &amp; Francis</general><general>Taylor &amp; Francis Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SE</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>7U7</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>H8G</scope><scope>JG9</scope><scope>KR7</scope><scope>L7M</scope><scope>P64</scope></search><sort><creationdate>20150721</creationdate><title>Development of a Method to Evaluate the Release Profile of Tamoxifen from Pegylated Hybrid Micelles</title><author>Claro de Souza, Marina ; Marotta-Oliveira, Samantha Sant'Anna ; Rocha, Nathália Helena Souza ; Eloy, Josimar O. ; Marchetti, Juliana Maldonado</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-4bace8bd7e0693035f844dc32fe9ceb241073d4e36333eec5b99281a0ca2ca393</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>analytical development and validation</topic><topic>drug delivery systems</topic><topic>hybrid pegylated micelles</topic><topic>in vitro release profile</topic><topic>RP-HPLC quantification</topic><topic>tamoxifen</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Claro de Souza, Marina</creatorcontrib><creatorcontrib>Marotta-Oliveira, Samantha Sant'Anna</creatorcontrib><creatorcontrib>Rocha, Nathália Helena Souza</creatorcontrib><creatorcontrib>Eloy, Josimar O.</creatorcontrib><creatorcontrib>Marchetti, Juliana Maldonado</creatorcontrib><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of liquid chromatography &amp; related technologies</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Claro de Souza, Marina</au><au>Marotta-Oliveira, Samantha Sant'Anna</au><au>Rocha, Nathália Helena Souza</au><au>Eloy, Josimar O.</au><au>Marchetti, Juliana Maldonado</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of a Method to Evaluate the Release Profile of Tamoxifen from Pegylated Hybrid Micelles</atitle><jtitle>Journal of liquid chromatography &amp; related technologies</jtitle><date>2015-07-21</date><risdate>2015</risdate><volume>38</volume><issue>12</issue><spage>1223</spage><epage>1229</epage><pages>1223-1229</pages><issn>1082-6076</issn><eissn>1520-572X</eissn><abstract>Studies of in vitro release profiles are important during the development of drug delivery systems. This article describes the development and validation of a RP-HPLC method for the quantification of drug released from tamoxifen-loaded DSPE-PEG(2000)/TPGS micelles and the determination of the best dissolution medium and apparatus for this assay. The method showed specificity, linearity, precision, accuracy, and robustness for the parameters evaluated (range 0.25-20.0 µg mL −1 ). The best dissolution medium was 1.0 mol L −1 sodium salicylate, pH 7.4, and the most suitable apparatus was a PVC tube with one end covered with a dialysis membrane. This method was shown to be useful for tamoxifen quantification in in vitro release studies.</abstract><cop>Abingdon</cop><pub>Taylor &amp; Francis</pub><doi>10.1080/10826076.2015.1032418</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1082-6076
ispartof Journal of liquid chromatography & related technologies, 2015-07, Vol.38 (12), p.1223-1229
issn 1082-6076
1520-572X
language eng
recordid cdi_crossref_primary_10_1080_10826076_2015_1032418
source Taylor and Francis Science and Technology Collection
subjects analytical development and validation
drug delivery systems
hybrid pegylated micelles
in vitro release profile
RP-HPLC quantification
tamoxifen
title Development of a Method to Evaluate the Release Profile of Tamoxifen from Pegylated Hybrid Micelles
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T14%3A04%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20a%20Method%20to%20Evaluate%20the%20Release%20Profile%20of%20Tamoxifen%20from%20Pegylated%20Hybrid%20Micelles&rft.jtitle=Journal%20of%20liquid%20chromatography%20&%20related%20technologies&rft.au=Claro%20de%20Souza,%20Marina&rft.date=2015-07-21&rft.volume=38&rft.issue=12&rft.spage=1223&rft.epage=1229&rft.pages=1223-1229&rft.issn=1082-6076&rft.eissn=1520-572X&rft_id=info:doi/10.1080/10826076.2015.1032418&rft_dat=%3Cproquest_cross%3E3707572091%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c338t-4bace8bd7e0693035f844dc32fe9ceb241073d4e36333eec5b99281a0ca2ca393%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1686445383&rft_id=info:pmid/&rfr_iscdi=true