Loading…
A Novel Antibacterial Membrane Electrode Based on Bacterial Cellulose/Polyaniline/AgNO 3 Composite for Bio-Potential Signal Monitoring
We propose a flexible, dry, and antibacterial electrode with a low and stable skin electrode contact impedance for bio-potential signal monitoring. We fabricated a bacterial cellulose/polyaniline/AgNO nanocomposite membrane (BC/PANI/AgNO ) and used it for bio-potential signal monitoring. The bacteri...
Saved in:
Published in: | IEEE journal of translational engineering in health and medicine 2018, Vol.6, p.2700310-10 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We propose a flexible, dry, and antibacterial electrode with a low and stable skin electrode contact impedance for bio-potential signal monitoring. We fabricated a bacterial cellulose/polyaniline/AgNO
nanocomposite membrane (BC/PANI/AgNO
) and used it for bio-potential signal monitoring. The bacterial cellulose (BC) provides a 3-D nanoporous network structure, and it was used as a substrate material in the BC/PANI/AgNO
nanocomposite membrane. Polyaniline (PANI) and AgNO
, acting as conductive and antibacterial components, respectively, were polymerized and deposited on the surfaces of BC nanofibers to produce uniform thin film membrane with flexible, antibacterial, and conductive properties. Various measurements were conducted, in terms of antibacterial activity, skin electrode contact impedance, and qualitative analysis of ECG signal recordings. The BC/PANI/AgNO3 membrane revealed 100% antibacterial activities against both the
and
bacteria. The skin electrode contact impedance of the proposed BC/PANI/AgNO
electrode is lower than that of the Ag/AgCl gel electrode, with the same active area. In addition, the electrocardiogram (ECG) signals acquired with the proposed electrodes have stable characteristic waveforms, and they are not contaminated by noise. The waveform fidelity of the BC/PANI/AgNO
membrane electrodes over 800 ECG cardiac cycles is 99.49%, and after the electrodes were worn for 24 hours, a fidelity of 98.40% was recorded over the same number of cardiac cycles. With the low and stable skin electrode contact impedance, the proposed dry BC/PANI/AgNO
membrane electrode provided high fidelity for ECG signal recordings, thus offering a potential approach for bio-potential signal monitoring. With the above benefits, the novel flexible and dry BC/PANI/AgNO
electrode has a significant antibacterial. Most of all, it is the first research to develop antibacterial in the electrode design. |
---|---|
ISSN: | 2168-2372 2168-2372 |
DOI: | 10.1109/JTEHM.2018.2863388 |