Auscultatory and Phonocardiographic Assessment of Pulmonary Stenosis with Intact Ventricular Septum
A clinical and phonocardiographic study has been made on pulmonary and infundibular stenosis with intact ventricular septum, in order to determine the value of auscultation and phonocardiography in assessing the severity of the stenosis. There were 43 cases of pulmonary valve stenosis with intact ve...
Saved in:
Published in: | Circulation (New York, N.Y.) N.Y.), 1960-07, Vol.22 (1), p.55-72 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A clinical and phonocardiographic study has been made on pulmonary and infundibular stenosis with intact ventricular septum, in order to determine the value of auscultation and phonocardiography in assessing the severity of the stenosis. There were 43 cases of pulmonary valve stenosis with intact ventricular septum and 8 cases of infundibular stenosis with intact ventricular septum.
The severity of the stenosis, as determined by the right ventricular pressure, was correlated with the duration of right ventricular systole, as determined both by the length of the systolic murmur and the width of splitting of the second heart sound. It was shown that increasingly severe stenosis resulted in progressive lengthening of the murmur in relation to the aortic second sound and delay in pulmonary valve closure. Criteria were defined whereby the severity of the stenosis could be predicted; these proved more accurate than other clinical methods.
In mild stenosis (RVP under 60 mm. Hg), the murmur was soft to loud in intensity, reached a crescendo in midsystole and ended before or at the aortic component of the second sound. The second sound was always abnormally split (average 0.05 second), and there was frequently a pulmonary ejection sound. In moderately severe stenosis (RVP 60 to 120 mm. Hg), the murmur was louder, the crescendo and duration greater, extending a short way beyond the aortic component, which it never obscured. Splitting was wider (average 0.07 second), and the pulmonary component was reduced in intensity. There was frequently a sharp, click-like first sound on expiration. In severe stenosis (RVP 120 to 180 mm. Hg), the murmur was loud with great delay in the crescendo and duration, resulting in a kite-shaped rather than a diamond-shaped configuration. It invariably extended well beyond the aortic component, which it either partially or completely buried. The murmur always ended before a very soft pulmonary component, which was widely separated from the aortic component (average 0.08 second). In very severe stenosis (RVP above 180 mm. Hg) the murmur was loud and so prolonged that it invariably obscured the aortic component, but ended before a very delayed (average 0.10 second) diminutive pulmonary component, which may or may not be heard. Whenever the aortic component was completely buried by the murmur, the great width of splitting could not be heard on auscultation, and phonocardiography was required for its detection. Thus, the length of murmur and t |
---|---|
ISSN: | 0009-7322 1524-4539 |