Loading…

Abstract 430: Spectral Changes Caused by Radiofrequency Ablation of Cardiac Tissue

Abstract only Persistent atrial fibrillation is commonly treated using an endoscopic catheter to eliminate anomalous sources of cardiac activity via thermal ablation. However, the procedure lacks real-time feedback. Newly developed radiofrequency ablation (RFA) catheters include a fiberoptic bundle...

Full description

Saved in:
Bibliographic Details
Published in:Circulation research 2016-07, Vol.119 (suppl_1)
Main Authors: Aljishi, Mohammed, Asfour, Huda, Chahbazian, Tigran, Muselimyan, Narine, Swift, Luther, Mercader, Marco, Sarvazyan, Narine
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract only Persistent atrial fibrillation is commonly treated using an endoscopic catheter to eliminate anomalous sources of cardiac activity via thermal ablation. However, the procedure lacks real-time feedback. Newly developed radiofrequency ablation (RFA) catheters include a fiberoptic bundle through which visual information of tissue conditions may be collected offering an opportunity to reveal subtle differences in tissue physiology. Currently little is known about the spectral changes caused by RFA. We hypothesized that by comparing spectral changes in various areas in the heart before and after RFA, optical signatures can be used to distinguish healthy cardiac tissue from thermally ablated tissue. Excitation emission matrices (EEM) were acquired from excised porcine hearts (300-600nm). Distinct EEMs were collected from the endocardium of the left atria, ventricle, and aorta. Additionally, the fluorescence and reflectance profiles of each tissue were altered by thermal ablation. In the ventricular muscle, a reduction in the NADH fluorescence peak (360/460nm excitation/emission maxima) was most prominent. While in the aorta, collagen and elastin fluorescence peaks fused and broadened upon ablation. Changes in atrial tissue included a drop in NADH fluorescence and an overall increase in reflectance. The latter is likely caused by thermal coagulation of heme-containing proteins such as myoglobin and a weaker absorption within the Soret band. We concluded that optical signals revealed by EEMs offer quantitative information that can be used to develop diagnostic catheters, including hyperspectral imaging protocols to discern spectral changes elicited by RFA treatment.
ISSN:0009-7330
1524-4571
DOI:10.1161/res.119.suppl_1.430