Bay 94-9027 Can be Accurately Measured across Regions with Appropriate One-Stage Assay Reagent Use

Introduction: Differences in coagulation assay reagents may lead to variable results for some extended-half-life (EHL) recombinant factor VIII (rFVIII) products, with the potential to adversely affect patient care. Laboratories assessing EHL-rFVIII activity can choose from many available one-stage a...

Full description

Saved in:
Bibliographic Details
Published in:Blood 2018-11, Vol.132 (Supplement 1), p.2481-2481
Main Authors: Pruthi, Rajiv K., Castellone, Donna D., Church, Nikki, Leong, Lilley, Kitchen, Steve
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction: Differences in coagulation assay reagents may lead to variable results for some extended-half-life (EHL) recombinant factor VIII (rFVIII) products, with the potential to adversely affect patient care. Laboratories assessing EHL-rFVIII activity can choose from many available one-stage assay and chromogenic assay reagents. A field study was conducted to evaluate the ability of clinical laboratories to accurately measure FVIII activity in plasma samples spiked with BAY 94-9027, an EHL rFVIII, when using diverse assay reagents and when guided in the choice of reagent. In a regional subanalysis, BAY 94-9027 field study results from clinical laboratories in the United States and Canada were compared with those from Europe and Israel. Methods: In this 2-part study, a broad range of laboratories in the United States, Canada, Europe (Austria, Germany, Italy, Romania, Spain, Switzerland, United Kingdom), and Israel were provided samples containing defined concentrations of BAY 94-9027 or an unmodified rFVIII (antihemophilic factor [recombinant] plasma/albumin-free method [rAHF-PFM]) as a control. In part 1, each laboratory measured FVIII activity using their routine methods (one-stage assay, chromogenic assay, or both); laboratories that had ≥2 routine one-stage assays were asked to perform sample testing with one of the less commonly used assays in the laboratory to ensure that part 1 captured both the prevalence and heterogeneity of one-stage assays used in the geographic regions studied. In part 2, laboratories used one-stage assays with SynthASil and Pathromtin SL reagents provided by Bayer; SynthASil and Pathromtin SL have previously been shown to accurately measure BAY 94-9027 and full-length rFVIII products. The field study data were analyzed to identify the most commonly used reagents in the 2 regions (United States/Canada and Europe/Israel) and to assess if regional differences resulted in differences in accuracy of FVIII activity measurement. Results: 52 laboratories (US/Canada, n=25; Europe/Israel, n=27) participated in the field study. The one-stage reagent SynthASil was commonly used in all countries (n=15) in part 1, but differences were seen in the frequency of use of other reagents. PTT-A (n=6) and Actin FSL (n=5) were frequently used in the US/Canada and Actin FS (n=6) and Pathromtin SL (n=6) in Europe/Israel. Regional differences in the choice of assay, with US/Canada more likely to use assays that did not accurately measure BAY 94-90
ISSN:0006-4971
1528-0020
DOI:10.1182/blood-2018-99-113493