Loading…

Automated diagnosis and grading of lumbar intervertebral disc degeneration based on a modified YOLO framework

The high prevalence of low back pain has led to an increasing demand for the analysis of lumbar magnetic resonance (MR) images. This study aimed to develop and evaluate a deep-learning-assisted automated system for diagnosing and grading lumbar intervertebral disc degeneration based on lumbar T2-wei...

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in bioengineering and biotechnology 2025-01, Vol.13, p.1526478
Main Authors: Wang, Aobo, Wang, Tianyi, Liu, Xingyu, Fan, Ning, Yuan, Shuo, Du, Peng, Zou, Congying, Chen, Ruiyuan, Xi, Yu, Gu, Zhao, Song, Hongxing, Fei, Qi, Zhang, Yiling, Zang, Lei
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The high prevalence of low back pain has led to an increasing demand for the analysis of lumbar magnetic resonance (MR) images. This study aimed to develop and evaluate a deep-learning-assisted automated system for diagnosing and grading lumbar intervertebral disc degeneration based on lumbar T2-weighted sagittal and axial MR images. This study included a total of 472 patients who underwent lumbar MR scans between January 2021 and November 2023, with 420 in the internal dataset and 52 in the external dataset. The MR images were evaluated and labeled by experts according to current guidelines, and the results were considered the ground truth. The annotations included the Pfirrmann grading of disc degeneration, disc herniation, and high-intensity zones (HIZ). The automated diagnostic model was based on the YOLOv5 network, modified by adding an attention module in the Cross Stage Partial part and a residual module in the Spatial Pyramid Pooling-Fast part. The model's diagnostic performance was evaluated by calculating the precision, recall, F1 score, and area under the receiver operating characteristic curve. In the internal test set, the model achieved precisions of 0.78-0.91, 0.90-0.92, and 0.82 and recalls of 0.86-0.91, 0.90-0.93, and 0.81-0.88 for disc degeneration grading, disc herniation diagnosis, and HIZ detection, respectively. In the external test set, the precision values for disc degeneration grading, herniation diagnosis, and HIZ detection were 0.73-0.87, 0.86-0.92, and 0.74-0.84 and recalls were 0.79-0.87, 0.88-0.91, and 0.77-0.78, respectively. The proposed model demonstrated a relatively high diagnostic and classification performance and exhibited considerable consistency with expert evaluation.
ISSN:2296-4185
2296-4185