Loading…

Optimization of the Outlet Shape of an Air Circulation System for Reduction of Indoor Temperature Difference

This study proposes an air circulation system that can forcibly circulate the lowest cold air to the top of indoor smart farms, and it has a width, length, and height of 6, 12, and 2.5 m, respectively, to reduce the effect of temperature differences between the upper and lower parts on the growth ra...

Full description

Saved in:
Bibliographic Details
Published in:Sensors (Basel, Switzerland) Switzerland), 2023-02, Vol.23 (5), p.2570
Main Authors: Park, Jin-Young, Yoo, Young-Jun, Kim, Young-Choon
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This study proposes an air circulation system that can forcibly circulate the lowest cold air to the top of indoor smart farms, and it has a width, length, and height of 6, 12, and 2.5 m, respectively, to reduce the effect of temperature differences between the upper and lower parts on the growth rate of plants in winter. This study also aimed to reduce the temperature deviation generated between the upper and lower parts of the target indoor space by optimizing the shape of the manufactured outlet of the air circulation system. A table of L9 orthogonal arrays, which is a design of experiment methodology, was used, and it presented three levels of the following design variables: blade angle, blade number, output height, and flow radius. Flow analysis was performed for the experiments on the nine models to minimize the high time and cost requirements. Based on the derived analysis results, an optimized prototype was manufactured by applying the Taguchi method, and experiments were conducted by installing 54 temperature points in an indoor space to identify the temperature difference between the upper and lower parts over time for the performance experiment. Under natural convection, the minimum temperature deviation was 2.2 °C and the temperature difference between the upper and lower parts did not decrease. For a model without an outlet shape, such as a vertical fan, the minimum temperature deviation was 0.8 °C and at least 530 s were required to reach a difference of less than 2 °C. When air was circulated in the air circulation system with the proposed outlet shape, the minimum temperature deviation was 0.6 °C and the time required to reach a difference of less than 2 °C was 440 s. Using the proposed air circulation system, cooling and heating costs are expected to be reduced in summer and winter because the arrival time and temperature difference between the upper and lower parts can be reduced using the outlet shape compared with the case without the outlet shape.
ISSN:1424-8220
1424-8220
DOI:10.3390/s23052570