Loading…
Parameter identification of transformer lumped element network model through genetic algorithm‐based gray‐box modelling technique
The lumped element network model has been proven to be an efficient tool for the interpretation of transformer Frequency Response Analysis. However, it is challenging to obtain parameters of the model if transformer design information is unavailable. In such a case, optimisation algorithms can be us...
Saved in:
Published in: | IET electric power applications 2024-03, Vol.18 (3), p.265-277 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The lumped element network model has been proven to be an efficient tool for the interpretation of transformer Frequency Response Analysis. However, it is challenging to obtain parameters of the model if transformer design information is unavailable. In such a case, optimisation algorithms can be used for gray‐box model parameter estimation. A methodology is developed by the authors to establish a transformer network model without winding design data, and instead, end‐to‐end open circuit Frequency Response and other terminal test results are utilised; and Genetic Algorithm is applied to approximate the unknown parameters of the model. The modelling approach developed is independent of the unit number of the network model and therefore guarantees the accuracy of optimisation. Furthermore, it can deal with transformers with a complicated winding structure such as interleaved disc type winding. Two single windings, helical and interleaved disc type, and a single‐phase 144/13 kV 60 MVA transformer are used to demonstrate the method. FRA spectra produced by the best estimated gray‐box model and the corresponding white‐box model are compared. The main features in amplitude and phase spectra are well matched, with low values of Relative Standard Deviation, for both single windings and transformer. Estimated electrical parameters show a high consistency with reference values, which are calculated based on winding design data. This validates the methodology and gives confidence to apply grey‐box modelling for FRA interpretation.
A methodology is developed to establish a transformer network model without winding design data, instead, end‐to‐end open circuit FRA and other terminal test results are utilised. The modelling approach developed is independent of the unit number of network therefore guarantee the accuracy of optimisation. Furthermore, it can deal with transformers with complicated winding structure such as interleaved disc type winding.Two single windings, helical and interleaved disc type, and a single‐phase 144/13 kV 60 MVA transformer are used to demonstrate the method. |
---|---|
ISSN: | 1751-8660 1751-8679 |
DOI: | 10.1049/elp2.12387 |