Transoral endoscopic thyroid surgery using robotic scope holder: Our initial experiences

Background: Transoral thyroid surgery represented by the da Vinci system is attracted attention and performed by several institutions. However, the current available da Vinci system still has some limitations to be improved for transoral thyroid surgery including high cost of equipment and expendabl...

Full description

Saved in:
Bibliographic Details
Published in:Journal of minimal access surgery 2020-07, Vol.16 (3), p.235-238
Main Authors: Park, Jun-Ook, Kim, Mi, Park, Yeong, Kim, Min-Sik, Sun, Dong-Il
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Transoral thyroid surgery represented by the da Vinci system is attracted attention and performed by several institutions. However, the current available da Vinci system still has some limitations to be improved for transoral thyroid surgery including high cost of equipment and expendables, larger diameter scope and instruments and no tactile sensation. It triggered us interest in more easily available robotic scope holder. Soloassist II (AktorMed GmbH, Barbing, Germany) is an active endoscope holder system which is controlled by a joystick. It has total six joints: three joints which are controlled by computer, one is controlled by manual and two act as a gimbal joint following the movement of the main body. Materials and Methods: We tried transoral endoscopic thyroidectomy using Soloassist II (AktorMed GmbH, Barbing, Germany) in December 2017 in our hospital. Results: We successfully performed four thyroid lobectomies in four patients with Soloassist II. We refined and described surgical procedures in each step using video clips. It provided an excellent vibration-free stable surgical view which enabled fatigue-free work, without shaking or tilting the horizon. The surgeon could perform transoral endoscopic thyroid surgery with only one assistant surgeon. Docking and preparation time for Soloassist was within 10 min in all four patients. The setup and dismantling could be performed parallel to the usual workflow. No complication was reported by any patient. Conclusions: The robotic scope holder (Soloassist II) seems to be safe and feasible equipment for performing transoral endoscopic thyroid surgery. Several possible advantages could be expected with this robotic scope holder.
ISSN:0972-9941
1998-3921
DOI:10.4103/jmas.JMAS_12_19