Evaluating carotid and aortic peak velocity variation as an alternative index for stroke volume and pulse pressure variation: a method comparison study

The peak velocity variation within the carotid artery (ΔVpeakCCA) and left ventricular outflow tract (ΔVpeakLVOT) is derived from the pulsed wave Doppler waveform and may predict fluid responsiveness. The aim of this study was to evaluate ΔVpeakCCA and ΔVpeakLVOT against calibrated stroke volume var...

Full description

Saved in:
Bibliographic Details
Published in:WFUMB Ultrasound Open 2023-06, Vol.1 (1), p.100001, Article 100001
Main Authors: van Houte, Joris, de Boer, Esmée C., van Knippenberg, Luuk, Suriani, Irene, Meesters, Michaël I., Meijs, Loek P.B., Montenij, Leon J., Bouwman, Arthur R.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The peak velocity variation within the carotid artery (ΔVpeakCCA) and left ventricular outflow tract (ΔVpeakLVOT) is derived from the pulsed wave Doppler waveform and may predict fluid responsiveness. The aim of this study was to evaluate ΔVpeakCCA and ΔVpeakLVOT against calibrated stroke volume variation (SVV) and pulse pressure variation (PVV). Therefore, eighteen cardiac surgery patients were included in this prospective observational study. Doppler measurements were performed after induction of anesthesia, after a passive leg raise, and at the end of surgery. Simultaneously, SVV and PPV were measured by pulse-contour-analysis (PiCCO). The correlation, methodological agreement, concordance, and clinical agreement between Doppler and PiCCO measurements were assessed. The correlation between SVV and ΔVpeakCCA was strong (ρ = 0.88). Bland-Altman analysis demonstrated a bias of 0.01%, and LOA +/− 4.6%, acceptable concordance (93%), and close to acceptable clinical agreement (88%). For PPV and ΔVpeakCCA correlation was also strong (ρ = 0.73), bias was −0.2%, LOA +/− 7.6%, with intermediate acceptable concordance (90%), and low clinical agreement (72%). Analysis of ΔVpeakLVOT measurements demonstrated poor statistical agreement with SVV and PPV. In conclusion, in cardiac surgery patients ΔVpeakCCA, as opposed to ΔVpeakLVOT, has acceptable statistical and clinical agreement with SVV measurements. ΔVpeakCCA may qualify as a potential tool for non-invasive assessment of fluid responsiveness.
ISSN:2949-6683
2949-6683
DOI:10.1016/j.wfumbo.2023.100001