Loading…

Reliability of shear-deficient RC beams strengthened with CFRP-strips

► Studied the reliability of shear-deficient and shear-strengthened RC beam specimens. ► All the beams were tested until failure to obtain their ultimate load capacities. ► Reliability analysis was carried out for a range of applied loads (service to ultimate). ► Studied the influence of fiber angle...

Full description

Saved in:
Bibliographic Details
Published in:Construction & building materials 2013-05, Vol.42, p.238-247
Main Authors: Alsayed, Saleh H., Siddiqui, Nadeem A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:► Studied the reliability of shear-deficient and shear-strengthened RC beam specimens. ► All the beams were tested until failure to obtain their ultimate load capacities. ► Reliability analysis was carried out for a range of applied loads (service to ultimate). ► Studied the influence of fiber angle; strip width; and strip-spacing on the reliability of beams. Effectiveness of externally bonded FRP-strips on the side faces of RC beams in the strengthening of shear-deficient RC beams is well established. However, how the design parameters such as fiber orientation, strip-width, and spacing between the FRP-strips influences the reliability of strengthened beams is not very well known. In the present study, a simplified probabilistic procedure based on Monte Carlo Simulation technique has been presented to study the influence of externally bonded FRP-strips on the reliability of shear-deficient RC beams. To illustrate the procedure, reliability analysis was carried out for the six RC beam specimens of 2m span. Two of these specimens were shear-deficient control specimens, and the remaining four were the similar beams which were shear-strengthened using CFRP-strips. Out of these four strengthened specimens, in the first two specimens, CFRP-strips were externally bonded at 30° whereas in the other two CFRP-strips were attached at 90° with the longitudinal axis of the beam. All these beams were tested in the lab until failure to obtain their ultimate load carrying capacities. Reliability analysis was then carried out for a range of applied nominal loads, varying from service to ultimate. Three parametric studies (i) effect of fiber orientation; (ii) effect of strip width; and (iii) effect of strip-spacing on reliability of strengthened beams were carried out for two different service loads, taken 60% and 70% of tested beams’ capacity. The results indicate that when the service load is 60% (or less) of the ultimate load, beam is sufficiently reliable for all the values of the fiber orientation ranging from 30° to 60° from the longitudinal axis of the beam. However, when the applied load is 70% (or more) of the ultimate load, it is difficult to achieve the desired reliability just by attaching the inclined CFRP strips at a certain angle. The desired reliability, in this case, can be achieved by altering the strip-width or strip-spacing or the both.
ISSN:0950-0618
1879-0526