Loading…

Microcapsule-based biosensor containing catechol for the reagent-free inhibitive detection of benzoic acid by tyrosinase

A biosensor based on the release of the enzyme substrate from its structure was developed for the inhibitive detection of benzoic acid. A polyurethane support comprising two perforated microcapsules (800 μm in diameter) filled with methylene blue as a model compound and covered with a conductive dep...

Full description

Saved in:
Bibliographic Details
Published in:Biosensors & bioelectronics 2021-05, Vol.180, p.113137, Article 113137
Main Authors: Nedellec, Yannig, Gondran, Chantal, Gorgy, Karine, Mc Murtry, Stefan, Agostini, Pierre, Elmazria, Omar, Cosnier, Serge
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A biosensor based on the release of the enzyme substrate from its structure was developed for the inhibitive detection of benzoic acid. A polyurethane support comprising two perforated microcapsules (800 μm in diameter) filled with methylene blue as a model compound and covered with a conductive deposit of multiwalled carbon nanotubes, continuously released this stored dye for 24 h. An increase in methylene blue concentration of 0.5–0.75 μmol L-1 h-1 and 1.5–2 μmol L-1 h-1, in the presence and absence of the multiwalled carbon nanotube coating, respectively, was demonstrated by UV–vis spectroscopy in a 2 mL UV cuvette. The same configuration with microcapsules filled with catechol was modified by a laponite clay coating containing tyrosinase enzyme. The resulting biosensor exhibits a constant cathodic current at −0.155 V vs AgCl/Ag, due to the reduction of the ortho-quinone produced enzymatically from the released catechol. The detection of benzoic acid was recorded from the decrease in cathodic current due to its inhibiting action on the tyrosinase activity. Reagentless biosensors based on different deposited quantity of tyrosinase (100, 200, 400 and 600 μg) were investigated for the detection of catechol and applied to the detection of benzoic acid as inhibitor. The best performance was obtained with the 400 μg-based configuration, namely a detection limit of 0.4 μmol L-1 and a sensitivity of 228 mA L mol−1. After the inhibition process, the biosensors recover 97–100% of their activity towards catechol, confirming a reversible inhibition by benzoic acid. •Amperometric biosensor based on perforated microcapsules containing enzyme substrate.•Inhibitory detection of benzoic acid by tyrosinase-based biosensor.•Enzyme biosensor based on slow continuous release of catechol as enzyme substrate.
ISSN:0956-5663
1873-4235
DOI:10.1016/j.bios.2021.113137