Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Metoprolol Succinate and Olmesartan Medoxomil in Bulk and in Formulation

An accurate, precise, robust and economic stability-indicating RP HPLC method for determination of Metoprolol succinate and Olmesartan medoxomil in bulk and in formulation has been developed and validated. Separation was carried out on HiQSil C18 column (250 x 4.6 mm, 5 μm) at flow rate of 1 ml/min...

Full description

Saved in:
Bibliographic Details
Published in:Research journal of pharmacy and technology 2014-12, Vol.7 (12), p.1368-1373
Main Authors: Singh, Anamika, Dwivedi, Jaya, Gandhi, Santosh V
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1373
container_issue 12
container_start_page 1368
container_title Research journal of pharmacy and technology
container_volume 7
creator Singh, Anamika
Dwivedi, Jaya
Gandhi, Santosh V
description An accurate, precise, robust and economic stability-indicating RP HPLC method for determination of Metoprolol succinate and Olmesartan medoxomil in bulk and in formulation has been developed and validated. Separation was carried out on HiQSil C18 column (250 x 4.6 mm, 5 μm) at flow rate of 1 ml/min using Methanol: 10 mM ophosphoric acid buffer (50: 50 v/v) and detection at 216 nm. On a stabilized chromatographic condition Metoprolol succinate and Olmesartan medoxomil gave acceptable peak at RT 3.66 ± 0.04 min and 18.14 ± 0.05 min, respectively. The calibration curve for Metoprolol succinate and Olmesartan medoxomil was found to be linear in the range 1–25 μg/ml and 1–10 μg/ml, respectively. The method was validated in accordance with international conference on harmonization (ICH) guidelines and prescribed stress conditions. The drugs were subjected to stress condition of hydrolysis (acid, base, neutral), oxidation, photolysis and thermal degradation. The proposed method can be applicable for the routine determination of Metoprolol succinate and Olmesartan medoxomil in bulk and formulation.
format article
fullrecord <record><control><sourceid>indianjournals</sourceid><recordid>TN_cdi_indianjournals_primary_rjpt_7_12_002_1368_1373</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rjpt_7_12_002_1368_1373</sourcerecordid><originalsourceid>FETCH-LOGICAL-i116t-3b252ef030178d06ceac081ac303da23e18b460fef107184cf0bc95062aa8943</originalsourceid><addsrcrecordid>eNo9T9tOAjEQ3RhNJMg_9Ac26WW3Wx4VREggECHGt023Fy122023a-Rr_FUrGuZh5mTOZTJX2QhOqyInFL5eXzBit9mk748wFWUlLtgo-56rT2V91yoXAXcSvHBrJI_GO-A12EfeGGviKV85aUTauzfwvMuXu_UMbFR89xJoH8BcRRVa4y7GxPkueOst2A9C_DLqnL-1rep5iNwljfRfvjUWGAceBvtxFiS88KEd7DnrLrvR3PZq8j_H2WHxeJgt8_X2aTW7X-cGIRpz0uASKw0JRBWTkArFBWSICwKJ5JgoxJqCQq00ghVihdCwEdMSUsw5mxZknJV_sSa9yd3RD8Glc3UXTMvDqQ7HLtZVjXANIa4RoSy1ipAfXSBvgA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Metoprolol Succinate and Olmesartan Medoxomil in Bulk and in Formulation</title><source>Alma/SFX Local Collection</source><creator>Singh, Anamika ; Dwivedi, Jaya ; Gandhi, Santosh V</creator><creatorcontrib>Singh, Anamika ; Dwivedi, Jaya ; Gandhi, Santosh V</creatorcontrib><description>An accurate, precise, robust and economic stability-indicating RP HPLC method for determination of Metoprolol succinate and Olmesartan medoxomil in bulk and in formulation has been developed and validated. Separation was carried out on HiQSil C18 column (250 x 4.6 mm, 5 μm) at flow rate of 1 ml/min using Methanol: 10 mM ophosphoric acid buffer (50: 50 v/v) and detection at 216 nm. On a stabilized chromatographic condition Metoprolol succinate and Olmesartan medoxomil gave acceptable peak at RT 3.66 ± 0.04 min and 18.14 ± 0.05 min, respectively. The calibration curve for Metoprolol succinate and Olmesartan medoxomil was found to be linear in the range 1–25 μg/ml and 1–10 μg/ml, respectively. The method was validated in accordance with international conference on harmonization (ICH) guidelines and prescribed stress conditions. The drugs were subjected to stress condition of hydrolysis (acid, base, neutral), oxidation, photolysis and thermal degradation. The proposed method can be applicable for the routine determination of Metoprolol succinate and Olmesartan medoxomil in bulk and formulation.</description><identifier>ISSN: 0974-3618</identifier><identifier>EISSN: 0974-360X</identifier><language>eng</language><publisher>A &amp; V Publications</publisher><subject>Metoprolol succinate ; Olmesartan medoxomil ; RP HPLC ; Stability</subject><ispartof>Research journal of pharmacy and technology, 2014-12, Vol.7 (12), p.1368-1373</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids></links><search><creatorcontrib>Singh, Anamika</creatorcontrib><creatorcontrib>Dwivedi, Jaya</creatorcontrib><creatorcontrib>Gandhi, Santosh V</creatorcontrib><title>Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Metoprolol Succinate and Olmesartan Medoxomil in Bulk and in Formulation</title><title>Research journal of pharmacy and technology</title><description>An accurate, precise, robust and economic stability-indicating RP HPLC method for determination of Metoprolol succinate and Olmesartan medoxomil in bulk and in formulation has been developed and validated. Separation was carried out on HiQSil C18 column (250 x 4.6 mm, 5 μm) at flow rate of 1 ml/min using Methanol: 10 mM ophosphoric acid buffer (50: 50 v/v) and detection at 216 nm. On a stabilized chromatographic condition Metoprolol succinate and Olmesartan medoxomil gave acceptable peak at RT 3.66 ± 0.04 min and 18.14 ± 0.05 min, respectively. The calibration curve for Metoprolol succinate and Olmesartan medoxomil was found to be linear in the range 1–25 μg/ml and 1–10 μg/ml, respectively. The method was validated in accordance with international conference on harmonization (ICH) guidelines and prescribed stress conditions. The drugs were subjected to stress condition of hydrolysis (acid, base, neutral), oxidation, photolysis and thermal degradation. The proposed method can be applicable for the routine determination of Metoprolol succinate and Olmesartan medoxomil in bulk and formulation.</description><subject>Metoprolol succinate</subject><subject>Olmesartan medoxomil</subject><subject>RP HPLC</subject><subject>Stability</subject><issn>0974-3618</issn><issn>0974-360X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNo9T9tOAjEQ3RhNJMg_9Ac26WW3Wx4VREggECHGt023Fy122023a-Rr_FUrGuZh5mTOZTJX2QhOqyInFL5eXzBit9mk748wFWUlLtgo-56rT2V91yoXAXcSvHBrJI_GO-A12EfeGGviKV85aUTauzfwvMuXu_UMbFR89xJoH8BcRRVa4y7GxPkueOst2A9C_DLqnL-1rep5iNwljfRfvjUWGAceBvtxFiS88KEd7DnrLrvR3PZq8j_H2WHxeJgt8_X2aTW7X-cGIRpz0uASKw0JRBWTkArFBWSICwKJ5JgoxJqCQq00ghVihdCwEdMSUsw5mxZknJV_sSa9yd3RD8Glc3UXTMvDqQ7HLtZVjXANIa4RoSy1ipAfXSBvgA</recordid><startdate>201412</startdate><enddate>201412</enddate><creator>Singh, Anamika</creator><creator>Dwivedi, Jaya</creator><creator>Gandhi, Santosh V</creator><general>A &amp; V Publications</general><scope/></search><sort><creationdate>201412</creationdate><title>Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Metoprolol Succinate and Olmesartan Medoxomil in Bulk and in Formulation</title><author>Singh, Anamika ; Dwivedi, Jaya ; Gandhi, Santosh V</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i116t-3b252ef030178d06ceac081ac303da23e18b460fef107184cf0bc95062aa8943</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Metoprolol succinate</topic><topic>Olmesartan medoxomil</topic><topic>RP HPLC</topic><topic>Stability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Singh, Anamika</creatorcontrib><creatorcontrib>Dwivedi, Jaya</creatorcontrib><creatorcontrib>Gandhi, Santosh V</creatorcontrib><jtitle>Research journal of pharmacy and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Singh, Anamika</au><au>Dwivedi, Jaya</au><au>Gandhi, Santosh V</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Metoprolol Succinate and Olmesartan Medoxomil in Bulk and in Formulation</atitle><jtitle>Research journal of pharmacy and technology</jtitle><date>2014-12</date><risdate>2014</risdate><volume>7</volume><issue>12</issue><spage>1368</spage><epage>1373</epage><pages>1368-1373</pages><issn>0974-3618</issn><eissn>0974-360X</eissn><abstract>An accurate, precise, robust and economic stability-indicating RP HPLC method for determination of Metoprolol succinate and Olmesartan medoxomil in bulk and in formulation has been developed and validated. Separation was carried out on HiQSil C18 column (250 x 4.6 mm, 5 μm) at flow rate of 1 ml/min using Methanol: 10 mM ophosphoric acid buffer (50: 50 v/v) and detection at 216 nm. On a stabilized chromatographic condition Metoprolol succinate and Olmesartan medoxomil gave acceptable peak at RT 3.66 ± 0.04 min and 18.14 ± 0.05 min, respectively. The calibration curve for Metoprolol succinate and Olmesartan medoxomil was found to be linear in the range 1–25 μg/ml and 1–10 μg/ml, respectively. The method was validated in accordance with international conference on harmonization (ICH) guidelines and prescribed stress conditions. The drugs were subjected to stress condition of hydrolysis (acid, base, neutral), oxidation, photolysis and thermal degradation. The proposed method can be applicable for the routine determination of Metoprolol succinate and Olmesartan medoxomil in bulk and formulation.</abstract><pub>A &amp; V Publications</pub><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0974-3618
ispartof Research journal of pharmacy and technology, 2014-12, Vol.7 (12), p.1368-1373
issn 0974-3618
0974-360X
language eng
recordid cdi_indianjournals_primary_rjpt_7_12_002_1368_1373
source Alma/SFX Local Collection
subjects Metoprolol succinate
Olmesartan medoxomil
RP HPLC
Stability
title Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Metoprolol Succinate and Olmesartan Medoxomil in Bulk and in Formulation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T12%3A49%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-indianjournals&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20Validation%20of%20Stability-Indicating%20RP-HPLC%20Method%20for%20Determination%20of%20Metoprolol%20Succinate%20and%20Olmesartan%20Medoxomil%20in%20Bulk%20and%20in%20Formulation&rft.jtitle=Research%20journal%20of%20pharmacy%20and%20technology&rft.au=Singh,%20Anamika&rft.date=2014-12&rft.volume=7&rft.issue=12&rft.spage=1368&rft.epage=1373&rft.pages=1368-1373&rft.issn=0974-3618&rft.eissn=0974-360X&rft_id=info:doi/&rft_dat=%3Cindianjournals%3Erjpt_7_12_002_1368_1373%3C/indianjournals%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-i116t-3b252ef030178d06ceac081ac303da23e18b460fef107184cf0bc95062aa8943%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true