Use of a head-tilting baseplate during volumetric-modulated arc therapy (VMAT) to better protect organs at risk in hippocampal sparing whole brain radiotherapy (HS-WBRT)

Coplanar arcs are used with limited arc range to prevent direct beam entrance through the lens, which is challenging for satisfactory planning of hippocampal sparing in whole brain radiotherapy (HS-WBRT) with VMAT. We evaluated the dosimetric impact of applying a head-tilting technique during VMAT,...

Full description

Saved in:
Bibliographic Details
Published in:PloS one 2020-04, Vol.15 (4), p.e0232430-e0232430
Main Authors: Oh, Se An, Yea, Ji Woon, Park, Jae Won, Park, Jaehyeon
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Coplanar arcs are used with limited arc range to prevent direct beam entrance through the lens, which is challenging for satisfactory planning of hippocampal sparing in whole brain radiotherapy (HS-WBRT) with VMAT. We evaluated the dosimetric impact of applying a head-tilting technique during VMAT, which allows unrestricted use of the arc range. Twenty patients with multiple brain metastases who had received two computed tomography (CT)-simulation sessions between January 2016 and December 2018 were included. One session was delivered in a traditional supine position; the other was delivered with a tilting acrylic supine baseplate (MedTec, USA) to elevate the patients' head by 40°. For each patient, a VMAT without (sVMAT) and with head-tilting (htVMAT) plan was generated. Conformity index (CI), homogeneity index (HI), and organ at risk (OAR) dose were evaluated. The Wilcoxon-signed test was used to compare the effect between two plans. The mean CI was 0.860±0.007 and 0.864±0.008 (p
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0232430