Loading…

Analytical Calculation of Synchronous Reactances of Homopolar Inductor Alternator

In this paper, the direct-axis (d-axis) and quadrature-axis (q-axis) synchronous reactances of homopolar inductor alternator (HIA) are calculated. First, an approximate 2-D model of HIA is developed and its relative air-gap permeance function is described. Then, the analytical expressions for the sy...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on plasma science 2015-05, Vol.43 (5), p.1462-1468
Main Authors: Lou, Z, Cheng, Y, He, Y, Shen, Q
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this paper, the direct-axis (d-axis) and quadrature-axis (q-axis) synchronous reactances of homopolar inductor alternator (HIA) are calculated. First, an approximate 2-D model of HIA is developed and its relative air-gap permeance function is described. Then, the analytical expressions for the synchronous reactances in the d-axis and q-axis are derived from magnetomotive force-relative air-gap permeance function theory, including armature reaction reactance and armature leakage reactance. Finally, theoretical results are compared with the simulation and experimental results.