Loading…

Accelerator mass spectrometry analysis of background 14C-concentrations in human blood: aiming at reference data for further microdosing studies

Objective Phase 0 clinical studies, which are known as microdose trials, are expected to promote drug development and reduce development costs. The accelerator mass spectrometry (AMS) system is expected to play an important role in the microdosing tests, as it is a highly sensitive measurement syste...

Full description

Saved in:
Bibliographic Details
Published in:Annals of nuclear medicine 2008-12, Vol.22 (10), p.883-889
Main Authors: Minamimoto, Ryogo, Hamabe, Yoshimi, Miyaoka, Teiji, Hara, Takamitsu, Yoshida, Keisuke, Oka, Takashi, Inoue, Tomio
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective Phase 0 clinical studies, which are known as microdose trials, are expected to promote drug development and reduce development costs. The accelerator mass spectrometry (AMS) system is expected to play an important role in the microdosing tests, as it is a highly sensitive measurement system that can be used to determine the drug concentrations in these tests. Using the AMS system, we measured the background 14 C-concentration in human blood and evaluated the data for use as a reference in microdose studies that administer 14 C-labeled compounds in humans. Methods Blood samples of five healthy Japanese volunteers (three men, two women, median age 40.4 ± 9.8 years) were collected around the same time and just prior to when the subjects ate a meal (between 12:00 noon and 2:00 pm). Centrifugal separations of blood that was allowed to clot and the plasma were performed at 503 g for 2 min at 4°C. Background 14 C-concentration for each of the samples was measured using the AMS system. The Institute of Accelerator Analysis, which is the first contract research organization in Japan that is capable of providing AMS analysis services for carbon dating and bioanalysis work, performed the AMS analysis. Results The mean 14 C-concentration in blood was 1.613 ± 0.125 dpm/ml (men 1.668 ± 0.114 dpm/ml, women 1.514 ± 0.076 dpm/ml), in clots 2.373 ± 0.087 dpm/ml (men 2.381 ± 0.101 dpm/ml, women 2.357 ± 0.060 dpm/ ml), and in plasma 0.648 ± 0.049 dpm/ml (men 0.647 ± 0.059 dpm/ml, women 0.649 ± 0.032 dpm/ml). The coefficient variation (CV) for blood was 7.8% (men 6.9%, women 5.0%), for clots 3.7% (men 4.3%, women 2.5%), and for plasma 7.6% (men 9.1%, women 4.9%). The 14 C-concentrations of the clot and blood were higher than those of plasma. The 14 C-concentrations in the blood and plasma were slightly different between individuals when compared with the values for the clot, although the differences were quite small, with a CV value less than 7.8%. Conclusions Even though the 14 C-concentration differed only slightly between individuals, 14 C-concentrations of the clot and blood were higher than those of the plasma. Therefore, the variation and difference of the background data for blood and plasma might be of use as a reference for microdosing test evaluations.
ISSN:0914-7187
1864-6433
DOI:10.1007/s12149-008-0200-x