Loading…

Palladium‐Based Metallic Glass with High Thrombogenic Resistance for Blood‐Contacting Medical Devices

Advancements in the design of mechanical blood circulatory devices have greatly improved patient survival rates, but currently employed metals still provoke a thrombosis response upon contact with blood, with potential life‐threatening consequences. While coating strategies have been developed to ad...

Full description

Saved in:
Bibliographic Details
Published in:Advanced functional materials 2022-01, Vol.32 (4), p.n/a
Main Authors: Cihova, Martina, Müller, Eike, Chandorkar, Yashoda, Thorwarth, Kerstin, Fortunato, Giuseppino, Maniura‐Weber, Katharina, Löffler, Jörg F., Rottmar, Markus
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Advancements in the design of mechanical blood circulatory devices have greatly improved patient survival rates, but currently employed metals still provoke a thrombosis response upon contact with blood, with potential life‐threatening consequences. While coating strategies have been developed to address this limitation, they possess inherent drawbacks such as susceptibility to crack formation and delamination. Herein, an amorphous metal based on palladium (Pd) is scrutinized and reveals substantial thrombogenic resistance compared to a state‐of‐the‐art titanium alloy. In vitro assessment with human whole blood shows that the Pd glass provokes reduced platelet activation (lower expression of CD62P, CD41/CD61) and greatly retarded fibrin formation, but pronounced platelet spreading therewith challenging the dogma that platelet spreading equals activation. Mechanistic analysis of the early biomaterial–blood interactions reveals that conformational changes of adhered fibrinogen, and modified αIIbβ3 integrin expression and distribution across adhered platelets, underlay the superior performance of Pd glass. The study is accompanied by structural and thermophysical bulk investigations and physicochemical surface characterization to link the materials properties with the observed blood response. The results reveal a remarkable potential of Pd‐based glass as direct blood‐contacting bulk material without the need for coating. Metallic biomaterials are inevitable for the functioning of mechanical blood pumps but induce a thrombosis response upon contact with blood that can be life‐threatening. This work showcases an amorphous metal based on noble palladium that largely outperforms a state‐of‐the‐art titanium alloy. Through combination of material and biological investigations, this work unravels mechanistic insights underlying the low thrombogenicity of Pd‐based metallic glass.
ISSN:1616-301X
1616-3028
DOI:10.1002/adfm.202108256