Validation of a gyrolabac assay for quantification of rituximab in human serum

Introduction: Gyrolabac technology presents a technology breakthrough for large molecule bioanalysis to support biologic drug development. The advantages of this innovative platform include fully automated nanoscale immunoassay capability, better assay reproducibility and data quality, small reagent...

Full description

Saved in:
Bibliographic Details
Published in:Journal of pharmacological and toxicological methods 2012-05, Vol.65 (3), p.107-114
Main Authors: Liu, Xiaodong F, Wang, Xun, Weaver, Roni J, Calliste, Laurelle, Xia, Christina, He, Yuyan J, Chen, LingSing
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction: Gyrolabac technology presents a technology breakthrough for large molecule bioanalysis to support biologic drug development. The advantages of this innovative platform include fully automated nanoscale immunoassay capability, better assay reproducibility and data quality, small reagent and sample volumes, and rapid assay development and validation as a result of reduced run time. Although Gyrolab has been increasingly used in method development in discovery environment, few fully validated Gyrolab assays have been reported. Here we report a method validation of a Gyrolab assay to determine rituximab levels in human serum. Methods: Rituximab is captured on a Bioaffyac CD by a biotinylated rat anti-idiotypic monoclonal antibody against rituximab and detected by an Alexa FluorARG-labeled anti-human IgG antibody. Assay conditions were optimized to give required sensitivity and dynamic range. The assay validation was conducted according to the current industry standards for GLP-regulated immunoassays. Results: The intrabatch precision and accuracy for the assay were determined using spiked human serum samples and shown to have a coefficient of variation (CV) of < 11% with a mean bias < 20%. The interbatch precision (CV) and absolute mean bias were both < 12% with the total error < 25%. Adequate spike recovery was demonstrated in serum samples of healthy individuals and solid tumor patients. The dilutional linearity test showed that the determined concentrations adjusted with various dilution factors had a linear relationship with the expected concentrations and that there was no hook effect. The method has been validated for the quantification of rituximab in human serum from 90 to 60,000 ng/mL with a minimum required dilution of 30.
ISSN:1056-8719
DOI:10.1016/j.vascn.2012.03.001