Loading…
Vibration-induced errors in MEMS tuning fork gyroscopes
This paper analyzes potential causes of vibration-induced error in ideal MEMS tuning fork gyroscopes. Even though MEMS gyros are known to be highly susceptible to mechanical vibration, the mechanisms responsible for generating vibration-induced errors are not well understood. We focus on the tuning...
Saved in:
Published in: | Sensors and actuators. A. Physical. 2012-06, Vol.180, p.32-44 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c396t-10ddd9b622f88ff7733d1d5118a17abf3b834642dfe1cf2c34b990e38190a99d3 |
---|---|
cites | cdi_FETCH-LOGICAL-c396t-10ddd9b622f88ff7733d1d5118a17abf3b834642dfe1cf2c34b990e38190a99d3 |
container_end_page | 44 |
container_issue | |
container_start_page | 32 |
container_title | Sensors and actuators. A. Physical. |
container_volume | 180 |
creator | Yoon, Sang Won Lee, Sangwoo Najafi, Khalil |
description | This paper analyzes potential causes of vibration-induced error in ideal MEMS tuning fork gyroscopes. Even though MEMS gyros are known to be highly susceptible to mechanical vibration, the mechanisms responsible for generating vibration-induced errors are not well understood. We focus on the tuning fork gyroscope (TFG) design that is known to be relatively immune to vibration because of its differential operation and common-mode rejection. Our analysis, however, demonstrates that even an ideal TFG cannot completely eliminate vibrations in special situations because of vibration-induced asymmetry and nonlinearity. We identify three major causes of error that arise from (1) capacitive nonlinearity at the sense electrode, (2) asymmetric electrostatic forces along sense direction at the drive electrodes, and (3) asymmetric electrostatic forces (i.e., drive-electrode capacitance) along drive direction at the drive electrodes. The occurrence conditions and characteristics of each cause are analyzed. The effects of the causes on three classes of TFG gyro designs are analyzed and compared both qualitatively and quantitatively using dynamic analysis and simulation. Interestingly, in our simulation conditions, one TFG design (denoted as Type-DD) is less sensitive to vibration (>99% reduction) than the other two TFG designs (denoted as Type-CP and Type-DS). The reason for this difference is that Type-DD gyroscopes are immune to the dominant cause of error afflicting Type-CP and Type-DS designs. Our analysis also demonstrates that the most critical error-generation condition is vibration along with the sense direction of gyroscopes (denoted as sense-direction vibration) because of its contribution to all causes of error. |
doi_str_mv | 10.1016/j.sna.2012.04.022 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1038266866</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0924424712002476</els_id><sourcerecordid>1038266866</sourcerecordid><originalsourceid>FETCH-LOGICAL-c396t-10ddd9b622f88ff7733d1d5118a17abf3b834642dfe1cf2c34b990e38190a99d3</originalsourceid><addsrcrecordid>eNp9kLlOAzEQQC0EEiHwAXRb0uziCx-iQlE4pEQUHK3l9RE5JHawd5Hy9zgKNdU0741mHgDXCHYIIna77krUHYYId5B2EOMTMEGCk5ZAJk_BBEpMW4opPwcXpawhhIRwPgH8M_RZDyHFNkQ7Gmcbl3PKpQmxWc6Xb80wxhBXjU_5q1ntcyom7Vy5BGdeb4q7-ptT8PE4f589t4vXp5fZw6I1RLKhRdBaK3uGsRfCe84JscjeISQ04rr3pBeEMoqtd8h4bAjtpYSOCCShltKSKbg57t3l9D26MqhtKMZtNjq6NBaFIBGYMcFYRdERNfXIkp1Xuxy2Ou8rpA6R1FrVSOoQSUGqaqTq3B8dV3_4CS6rYoKLNUPIzgzKpvCP_QuEDG6R</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1038266866</pqid></control><display><type>article</type><title>Vibration-induced errors in MEMS tuning fork gyroscopes</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Yoon, Sang Won ; Lee, Sangwoo ; Najafi, Khalil</creator><creatorcontrib>Yoon, Sang Won ; Lee, Sangwoo ; Najafi, Khalil</creatorcontrib><description>This paper analyzes potential causes of vibration-induced error in ideal MEMS tuning fork gyroscopes. Even though MEMS gyros are known to be highly susceptible to mechanical vibration, the mechanisms responsible for generating vibration-induced errors are not well understood. We focus on the tuning fork gyroscope (TFG) design that is known to be relatively immune to vibration because of its differential operation and common-mode rejection. Our analysis, however, demonstrates that even an ideal TFG cannot completely eliminate vibrations in special situations because of vibration-induced asymmetry and nonlinearity. We identify three major causes of error that arise from (1) capacitive nonlinearity at the sense electrode, (2) asymmetric electrostatic forces along sense direction at the drive electrodes, and (3) asymmetric electrostatic forces (i.e., drive-electrode capacitance) along drive direction at the drive electrodes. The occurrence conditions and characteristics of each cause are analyzed. The effects of the causes on three classes of TFG gyro designs are analyzed and compared both qualitatively and quantitatively using dynamic analysis and simulation. Interestingly, in our simulation conditions, one TFG design (denoted as Type-DD) is less sensitive to vibration (>99% reduction) than the other two TFG designs (denoted as Type-CP and Type-DS). The reason for this difference is that Type-DD gyroscopes are immune to the dominant cause of error afflicting Type-CP and Type-DS designs. Our analysis also demonstrates that the most critical error-generation condition is vibration along with the sense direction of gyroscopes (denoted as sense-direction vibration) because of its contribution to all causes of error.</description><identifier>ISSN: 0924-4247</identifier><identifier>EISSN: 1873-3069</identifier><identifier>DOI: 10.1016/j.sna.2012.04.022</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Asymmetry ; Design engineering ; Electrodes ; Error detection ; Errors ; Gyroscope modeling ; Gyroscopes ; Microelectromechanical systems (MEMS) ; Nonlinear capacitance ; Tuning fork gyroscopes ; Vibration ; Vibration sensitivity</subject><ispartof>Sensors and actuators. A. Physical., 2012-06, Vol.180, p.32-44</ispartof><rights>2012 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c396t-10ddd9b622f88ff7733d1d5118a17abf3b834642dfe1cf2c34b990e38190a99d3</citedby><cites>FETCH-LOGICAL-c396t-10ddd9b622f88ff7733d1d5118a17abf3b834642dfe1cf2c34b990e38190a99d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Yoon, Sang Won</creatorcontrib><creatorcontrib>Lee, Sangwoo</creatorcontrib><creatorcontrib>Najafi, Khalil</creatorcontrib><title>Vibration-induced errors in MEMS tuning fork gyroscopes</title><title>Sensors and actuators. A. Physical.</title><description>This paper analyzes potential causes of vibration-induced error in ideal MEMS tuning fork gyroscopes. Even though MEMS gyros are known to be highly susceptible to mechanical vibration, the mechanisms responsible for generating vibration-induced errors are not well understood. We focus on the tuning fork gyroscope (TFG) design that is known to be relatively immune to vibration because of its differential operation and common-mode rejection. Our analysis, however, demonstrates that even an ideal TFG cannot completely eliminate vibrations in special situations because of vibration-induced asymmetry and nonlinearity. We identify three major causes of error that arise from (1) capacitive nonlinearity at the sense electrode, (2) asymmetric electrostatic forces along sense direction at the drive electrodes, and (3) asymmetric electrostatic forces (i.e., drive-electrode capacitance) along drive direction at the drive electrodes. The occurrence conditions and characteristics of each cause are analyzed. The effects of the causes on three classes of TFG gyro designs are analyzed and compared both qualitatively and quantitatively using dynamic analysis and simulation. Interestingly, in our simulation conditions, one TFG design (denoted as Type-DD) is less sensitive to vibration (>99% reduction) than the other two TFG designs (denoted as Type-CP and Type-DS). The reason for this difference is that Type-DD gyroscopes are immune to the dominant cause of error afflicting Type-CP and Type-DS designs. Our analysis also demonstrates that the most critical error-generation condition is vibration along with the sense direction of gyroscopes (denoted as sense-direction vibration) because of its contribution to all causes of error.</description><subject>Asymmetry</subject><subject>Design engineering</subject><subject>Electrodes</subject><subject>Error detection</subject><subject>Errors</subject><subject>Gyroscope modeling</subject><subject>Gyroscopes</subject><subject>Microelectromechanical systems (MEMS)</subject><subject>Nonlinear capacitance</subject><subject>Tuning fork gyroscopes</subject><subject>Vibration</subject><subject>Vibration sensitivity</subject><issn>0924-4247</issn><issn>1873-3069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp9kLlOAzEQQC0EEiHwAXRb0uziCx-iQlE4pEQUHK3l9RE5JHawd5Hy9zgKNdU0741mHgDXCHYIIna77krUHYYId5B2EOMTMEGCk5ZAJk_BBEpMW4opPwcXpawhhIRwPgH8M_RZDyHFNkQ7Gmcbl3PKpQmxWc6Xb80wxhBXjU_5q1ntcyom7Vy5BGdeb4q7-ptT8PE4f589t4vXp5fZw6I1RLKhRdBaK3uGsRfCe84JscjeISQ04rr3pBeEMoqtd8h4bAjtpYSOCCShltKSKbg57t3l9D26MqhtKMZtNjq6NBaFIBGYMcFYRdERNfXIkp1Xuxy2Ou8rpA6R1FrVSOoQSUGqaqTq3B8dV3_4CS6rYoKLNUPIzgzKpvCP_QuEDG6R</recordid><startdate>201206</startdate><enddate>201206</enddate><creator>Yoon, Sang Won</creator><creator>Lee, Sangwoo</creator><creator>Najafi, Khalil</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>201206</creationdate><title>Vibration-induced errors in MEMS tuning fork gyroscopes</title><author>Yoon, Sang Won ; Lee, Sangwoo ; Najafi, Khalil</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c396t-10ddd9b622f88ff7733d1d5118a17abf3b834642dfe1cf2c34b990e38190a99d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Asymmetry</topic><topic>Design engineering</topic><topic>Electrodes</topic><topic>Error detection</topic><topic>Errors</topic><topic>Gyroscope modeling</topic><topic>Gyroscopes</topic><topic>Microelectromechanical systems (MEMS)</topic><topic>Nonlinear capacitance</topic><topic>Tuning fork gyroscopes</topic><topic>Vibration</topic><topic>Vibration sensitivity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yoon, Sang Won</creatorcontrib><creatorcontrib>Lee, Sangwoo</creatorcontrib><creatorcontrib>Najafi, Khalil</creatorcontrib><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. A. Physical.</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yoon, Sang Won</au><au>Lee, Sangwoo</au><au>Najafi, Khalil</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Vibration-induced errors in MEMS tuning fork gyroscopes</atitle><jtitle>Sensors and actuators. A. Physical.</jtitle><date>2012-06</date><risdate>2012</risdate><volume>180</volume><spage>32</spage><epage>44</epage><pages>32-44</pages><issn>0924-4247</issn><eissn>1873-3069</eissn><abstract>This paper analyzes potential causes of vibration-induced error in ideal MEMS tuning fork gyroscopes. Even though MEMS gyros are known to be highly susceptible to mechanical vibration, the mechanisms responsible for generating vibration-induced errors are not well understood. We focus on the tuning fork gyroscope (TFG) design that is known to be relatively immune to vibration because of its differential operation and common-mode rejection. Our analysis, however, demonstrates that even an ideal TFG cannot completely eliminate vibrations in special situations because of vibration-induced asymmetry and nonlinearity. We identify three major causes of error that arise from (1) capacitive nonlinearity at the sense electrode, (2) asymmetric electrostatic forces along sense direction at the drive electrodes, and (3) asymmetric electrostatic forces (i.e., drive-electrode capacitance) along drive direction at the drive electrodes. The occurrence conditions and characteristics of each cause are analyzed. The effects of the causes on three classes of TFG gyro designs are analyzed and compared both qualitatively and quantitatively using dynamic analysis and simulation. Interestingly, in our simulation conditions, one TFG design (denoted as Type-DD) is less sensitive to vibration (>99% reduction) than the other two TFG designs (denoted as Type-CP and Type-DS). The reason for this difference is that Type-DD gyroscopes are immune to the dominant cause of error afflicting Type-CP and Type-DS designs. Our analysis also demonstrates that the most critical error-generation condition is vibration along with the sense direction of gyroscopes (denoted as sense-direction vibration) because of its contribution to all causes of error.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.sna.2012.04.022</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0924-4247 |
ispartof | Sensors and actuators. A. Physical., 2012-06, Vol.180, p.32-44 |
issn | 0924-4247 1873-3069 |
language | eng |
recordid | cdi_proquest_miscellaneous_1038266866 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Asymmetry Design engineering Electrodes Error detection Errors Gyroscope modeling Gyroscopes Microelectromechanical systems (MEMS) Nonlinear capacitance Tuning fork gyroscopes Vibration Vibration sensitivity |
title | Vibration-induced errors in MEMS tuning fork gyroscopes |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T18%3A18%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Vibration-induced%20errors%20in%20MEMS%20tuning%20fork%20gyroscopes&rft.jtitle=Sensors%20and%20actuators.%20A.%20Physical.&rft.au=Yoon,%20Sang%20Won&rft.date=2012-06&rft.volume=180&rft.spage=32&rft.epage=44&rft.pages=32-44&rft.issn=0924-4247&rft.eissn=1873-3069&rft_id=info:doi/10.1016/j.sna.2012.04.022&rft_dat=%3Cproquest_cross%3E1038266866%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c396t-10ddd9b622f88ff7733d1d5118a17abf3b834642dfe1cf2c34b990e38190a99d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1038266866&rft_id=info:pmid/&rfr_iscdi=true |