Loading…

Impact of delay after biopsy and post-biopsy haemorrhage on prostate cancer tumour detection using multi-parametric MRI: A multi-reader study

Aim To assess impact of haemorrhage and delay after biopsy on prostate tumour detection using multi-parametric (MP) magnetic resonance imaging (MRI) assessment. Materials and methods Forty-four patients underwent prostate MRI at 1.5 T using a pelvic phased-array coil, including T1-weighted imaging (...

Full description

Saved in:
Bibliographic Details
Published in:Clinical radiology 2012-12, Vol.67 (12), p.e83-e90
Main Authors: Rosenkrantz, A.B, Mussi, T.C, Hindman, N, Lim, R.P, Kong, M.X, Babb, J.S, Melamed, J, Taneja, S.S
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Aim To assess impact of haemorrhage and delay after biopsy on prostate tumour detection using multi-parametric (MP) magnetic resonance imaging (MRI) assessment. Materials and methods Forty-four patients underwent prostate MRI at 1.5 T using a pelvic phased-array coil, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging, before prostatectomy. Three radiologists independently reviewed images during four sessions [T2WI, DWI, DCE, and all parameters combined (MP-MRI)] to assess for tumour in each sextant. In a separate session, readers reviewed T1WI to score the extent of haemorrhage per sextant. Accuracy was assessed using logistic regression for correlated data. Results There was no significant difference in accuracy between readers for any session ( p  ≥ 0.166), and results were averaged across the three readers for remaining comparisons. Accuracy was significantly greater for MP-MRI than for any parameter alone ( p  ≤ 0.020). For T2WI alone, there was a trend toward decreased sensitivity in sextants with extensive haemorrhage ( p  = 0.072). However, accuracy, sensitivity, and specificity were otherwise similar for sextants with and without extensive haemorrhage for all sessions ( p  = 0.192–0.934). No session showed a significant improvement in accuracy, sensitivity, or specificity in cases with delay after biopsy of over 4 weeks compared with shorter delay. Conclusion Extensive haemorrhage and short delay after biopsy did not negatively impact accuracy for tumour detection using MP-MRI. Further studies using MP-MRI protocols and interpretation schemes from other institutions are required to confirm these observations.
ISSN:0009-9260
1365-229X
DOI:10.1016/j.crad.2012.08.014