An optoelectric plantar "shear" sensing transducer: design, validation, and preliminary subject tests

A prototype miniature plantar shear sensing transducer was developed, characterized, and tested in this study. Electro-optical components were chosen for the design because of the fast response time, low cost, small size, low power requirements, and adaptability to this application. The optoelectric...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on rehabilitation engineering 1996-12, Vol.4 (4), p.310-319
Main Authors: Lebar, A.M., Harris, G.F., Wertsch, J.J., Hongsheng Zhu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A prototype miniature plantar shear sensing transducer was developed, characterized, and tested in this study. Electro-optical components were chosen for the design because of the fast response time, low cost, small size, low power requirements, and adaptability to this application. The optoelectric circuit employed a 660 nm wavelength light source and photodiode solar cell. Signal amplification and sensitivity were adjusted to provide an output voltage proportional to light power. The sensor shell was designed to encapsulate the electro-optical sensing components while providing mechanical resistance to shear through a spring mechanism. A naval bronze was chosen for the shell due to its strength and nonreflective characteristics (alloy of copper and tin). Static and dynamic characteristics of the shear sensor were determined through a series of calibration tests. Mechanical crosstalk sensitivity ranged from 14.34 to 30.51 mV/N. This represented 1% full-scale/Newton sensitivity. Nonlinearity averaged 5.6% in the forward direction and 7.6% in the reverse direction. Overall sensor output hysteresis was 1.1/spl plusmn/3.1% while the natural frequency of the sensor to an input shear transient was approximately 5 Hz. Temperature sensitivity was -7.0 mV//spl deg/C or 3.5% full-scale//spl deg/C. Testing of five adult subjects revealed peak anterior-posterior shear ranging from 6.7 kPa (posterior heel) to 51.4 kPa (great toe) and medial-lateral shear ranging from 5.4 kPa (great toe) to 43.5 kPa (first metatarsal head). Stress-time integral values ranged from 0.78 kPa-sec (posterior shear at the posterior heel) to 37.3 kPa-sec (medial shear at the posterior heel). Contact durations ranged from 0.28 sec (posterior shear at the posterior heel) to 1.25 sec (medial shear at the posterior heel). Further application of the sensor for plantar shear characterization in able-bodied subjects and those with pathology is suggested.
ISSN:1063-6528
1558-0024