Loading…

High Levels of Airborne Ultrafine and Fine Particulate Matter in Indoor Ice Arenas

The high prevalence of airway dysfunction among ice arena athletes may be related to rink air exposure; in particular, high concentrations of ultrafine and fine particulate matter (0.02-1.0 µm diameter, PM 1) from ice resurfacing machines may enhance airway inflammation and hyperreactivity. The purp...

Full description

Saved in:
Bibliographic Details
Published in:Inhalation toxicology 2003-03, Vol.15 (3), p.237-250
Main Author: Rundell, Kenneth W.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c518t-20fb3f472f7cdab0aa02d9b2fdbd8129a1f4ba870d6f3e9c9be2d31cbc4262943
cites
container_end_page 250
container_issue 3
container_start_page 237
container_title Inhalation toxicology
container_volume 15
creator Rundell, Kenneth W.
description The high prevalence of airway dysfunction among ice arena athletes may be related to rink air exposure; in particular, high concentrations of ultrafine and fine particulate matter (0.02-1.0 µm diameter, PM 1) from ice resurfacing machines may enhance airway inflammation and hyperreactivity. The purpose of this study was to identify levels of PM 1 emitted from ice resurfacing machines used in indoor ice arenas, and to compare [PM 1] pre- and post-resurfacing to each other and to outdoor [PM 1] . Multiple one Hz measurements were recorded on 28 different days as 15-s mean of PM 1 ·cm -3 for 2 min at 1-1.5 m "above ice" in 10 rinks pre- and post-resurfacing, with measured airborne PM 1 outside each rink to be used individual rink references. Rink PM 1 ·cm -3 was ~30 times greater than PM 1 ·cm -3 outside the respective rinks (p < .05). Rink values were 104.2 ± 59.3 × 10 3 PM 1 ·cm -3 during prime usage, compared to outdoor values of 3.8 ± 2.5 × 10 3 PM 1 ·cm -3. Ice resurfacing increased PM 1 ·cm -3 4-fold (p < .05). No difference in PM 1 emissions between gasoline and propane powered resurfacing machines was identified. The rate of PM 1 dissipation after resurfacing was highly variable between rinks and probably dependent upon rink ventilation and resurfacing machine engine efficiency. Gas-powered edging increased PM 1 ·cm -3 18-fold and 158-fold versus pre-edging rink and outdoor values, respectively. We conclude that the primary source of airborne indoor rink PM 1 is internal combustion ice-resurfacing machines and that this poor air quality may be causal to the unique and high prevalence of airway dysfunction in ice arena athletes.
doi_str_mv 10.1080/08958370304502
format article
fullrecord <record><control><sourceid>proquest_infor</sourceid><recordid>TN_cdi_proquest_miscellaneous_16163172</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>16163172</sourcerecordid><originalsourceid>FETCH-LOGICAL-c518t-20fb3f472f7cdab0aa02d9b2fdbd8129a1f4ba870d6f3e9c9be2d31cbc4262943</originalsourceid><addsrcrecordid>eNqFkM1rVDEUxYModqxuXUpW7l7Nx3svL8uhWDswRRG7DjdfTkomqUlepf-9b5iB0kVxdQ-c3zlcDkIfKbmgZCJfyCSHiQvCST8Q9gqtKJG0E6Okr9HqYHaLO52hd7XeEUJGwsVbdEbZIGQ_DCv08zr83uGte3Cx4uzxOhSdS3L4NrYCPiwKksVXB_EDSgtmjtAcvoHWXMEh4U2yORe8MQ6vi0tQ36M3HmJ1H073HN1eff11ed1tv3_bXK63nRno1DpGvOa-F8wLY0ETAMKs1MxbbSfKJFDfa5gEsaPnThqpHbOcGm16NjLZ83P0-dh7X_Kf2dWm9qEaFyMkl-eq6EhHTgX7P9iPAyOCL-DFETQl11qcV_cl7KE8KkrUYW71fO4l8OnUPOu9s0_4ad8FkEcgJJ_LHv7mEq1q8Bhz8QWSCVXxF8unZ9mdg9h2BopTd3kuadn2pb_-AYKfnc4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14652073</pqid></control><display><type>article</type><title>High Levels of Airborne Ultrafine and Fine Particulate Matter in Indoor Ice Arenas</title><source>Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list)</source><creator>Rundell, Kenneth W.</creator><creatorcontrib>Rundell, Kenneth W.</creatorcontrib><description>The high prevalence of airway dysfunction among ice arena athletes may be related to rink air exposure; in particular, high concentrations of ultrafine and fine particulate matter (0.02-1.0 µm diameter, PM 1) from ice resurfacing machines may enhance airway inflammation and hyperreactivity. The purpose of this study was to identify levels of PM 1 emitted from ice resurfacing machines used in indoor ice arenas, and to compare [PM 1] pre- and post-resurfacing to each other and to outdoor [PM 1] . Multiple one Hz measurements were recorded on 28 different days as 15-s mean of PM 1 ·cm -3 for 2 min at 1-1.5 m "above ice" in 10 rinks pre- and post-resurfacing, with measured airborne PM 1 outside each rink to be used individual rink references. Rink PM 1 ·cm -3 was ~30 times greater than PM 1 ·cm -3 outside the respective rinks (p &lt; .05). Rink values were 104.2 ± 59.3 × 10 3 PM 1 ·cm -3 during prime usage, compared to outdoor values of 3.8 ± 2.5 × 10 3 PM 1 ·cm -3. Ice resurfacing increased PM 1 ·cm -3 4-fold (p &lt; .05). No difference in PM 1 emissions between gasoline and propane powered resurfacing machines was identified. The rate of PM 1 dissipation after resurfacing was highly variable between rinks and probably dependent upon rink ventilation and resurfacing machine engine efficiency. Gas-powered edging increased PM 1 ·cm -3 18-fold and 158-fold versus pre-edging rink and outdoor values, respectively. We conclude that the primary source of airborne indoor rink PM 1 is internal combustion ice-resurfacing machines and that this poor air quality may be causal to the unique and high prevalence of airway dysfunction in ice arena athletes.</description><identifier>ISSN: 0895-8378</identifier><identifier>EISSN: 1091-7691</identifier><identifier>DOI: 10.1080/08958370304502</identifier><identifier>PMID: 12579455</identifier><language>eng</language><publisher>England: Informa UK Ltd</publisher><subject>Air Pollutants - analysis ; Air Pollution, Indoor - analysis ; Bronchial Hyperreactivity - etiology ; Environmental Illness - etiology ; Particle Size ; Skating ; Vehicle Emissions - analysis</subject><ispartof>Inhalation toxicology, 2003-03, Vol.15 (3), p.237-250</ispartof><rights>2003 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 2003</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c518t-20fb3f472f7cdab0aa02d9b2fdbd8129a1f4ba870d6f3e9c9be2d31cbc4262943</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12579455$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rundell, Kenneth W.</creatorcontrib><title>High Levels of Airborne Ultrafine and Fine Particulate Matter in Indoor Ice Arenas</title><title>Inhalation toxicology</title><addtitle>Inhal Toxicol</addtitle><description>The high prevalence of airway dysfunction among ice arena athletes may be related to rink air exposure; in particular, high concentrations of ultrafine and fine particulate matter (0.02-1.0 µm diameter, PM 1) from ice resurfacing machines may enhance airway inflammation and hyperreactivity. The purpose of this study was to identify levels of PM 1 emitted from ice resurfacing machines used in indoor ice arenas, and to compare [PM 1] pre- and post-resurfacing to each other and to outdoor [PM 1] . Multiple one Hz measurements were recorded on 28 different days as 15-s mean of PM 1 ·cm -3 for 2 min at 1-1.5 m "above ice" in 10 rinks pre- and post-resurfacing, with measured airborne PM 1 outside each rink to be used individual rink references. Rink PM 1 ·cm -3 was ~30 times greater than PM 1 ·cm -3 outside the respective rinks (p &lt; .05). Rink values were 104.2 ± 59.3 × 10 3 PM 1 ·cm -3 during prime usage, compared to outdoor values of 3.8 ± 2.5 × 10 3 PM 1 ·cm -3. Ice resurfacing increased PM 1 ·cm -3 4-fold (p &lt; .05). No difference in PM 1 emissions between gasoline and propane powered resurfacing machines was identified. The rate of PM 1 dissipation after resurfacing was highly variable between rinks and probably dependent upon rink ventilation and resurfacing machine engine efficiency. Gas-powered edging increased PM 1 ·cm -3 18-fold and 158-fold versus pre-edging rink and outdoor values, respectively. We conclude that the primary source of airborne indoor rink PM 1 is internal combustion ice-resurfacing machines and that this poor air quality may be causal to the unique and high prevalence of airway dysfunction in ice arena athletes.</description><subject>Air Pollutants - analysis</subject><subject>Air Pollution, Indoor - analysis</subject><subject>Bronchial Hyperreactivity - etiology</subject><subject>Environmental Illness - etiology</subject><subject>Particle Size</subject><subject>Skating</subject><subject>Vehicle Emissions - analysis</subject><issn>0895-8378</issn><issn>1091-7691</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNqFkM1rVDEUxYModqxuXUpW7l7Nx3svL8uhWDswRRG7DjdfTkomqUlepf-9b5iB0kVxdQ-c3zlcDkIfKbmgZCJfyCSHiQvCST8Q9gqtKJG0E6Okr9HqYHaLO52hd7XeEUJGwsVbdEbZIGQ_DCv08zr83uGte3Cx4uzxOhSdS3L4NrYCPiwKksVXB_EDSgtmjtAcvoHWXMEh4U2yORe8MQ6vi0tQ36M3HmJ1H073HN1eff11ed1tv3_bXK63nRno1DpGvOa-F8wLY0ETAMKs1MxbbSfKJFDfa5gEsaPnThqpHbOcGm16NjLZ83P0-dh7X_Kf2dWm9qEaFyMkl-eq6EhHTgX7P9iPAyOCL-DFETQl11qcV_cl7KE8KkrUYW71fO4l8OnUPOu9s0_4ad8FkEcgJJ_LHv7mEq1q8Bhz8QWSCVXxF8unZ9mdg9h2BopTd3kuadn2pb_-AYKfnc4</recordid><startdate>20030301</startdate><enddate>20030301</enddate><creator>Rundell, Kenneth W.</creator><general>Informa UK Ltd</general><general>Taylor &amp; Francis</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7T2</scope><scope>7TV</scope><scope>7U2</scope><scope>7U7</scope></search><sort><creationdate>20030301</creationdate><title>High Levels of Airborne Ultrafine and Fine Particulate Matter in Indoor Ice Arenas</title><author>Rundell, Kenneth W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c518t-20fb3f472f7cdab0aa02d9b2fdbd8129a1f4ba870d6f3e9c9be2d31cbc4262943</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Air Pollutants - analysis</topic><topic>Air Pollution, Indoor - analysis</topic><topic>Bronchial Hyperreactivity - etiology</topic><topic>Environmental Illness - etiology</topic><topic>Particle Size</topic><topic>Skating</topic><topic>Vehicle Emissions - analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rundell, Kenneth W.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Pollution Abstracts</collection><collection>Safety Science and Risk</collection><collection>Toxicology Abstracts</collection><jtitle>Inhalation toxicology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rundell, Kenneth W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High Levels of Airborne Ultrafine and Fine Particulate Matter in Indoor Ice Arenas</atitle><jtitle>Inhalation toxicology</jtitle><addtitle>Inhal Toxicol</addtitle><date>2003-03-01</date><risdate>2003</risdate><volume>15</volume><issue>3</issue><spage>237</spage><epage>250</epage><pages>237-250</pages><issn>0895-8378</issn><eissn>1091-7691</eissn><abstract>The high prevalence of airway dysfunction among ice arena athletes may be related to rink air exposure; in particular, high concentrations of ultrafine and fine particulate matter (0.02-1.0 µm diameter, PM 1) from ice resurfacing machines may enhance airway inflammation and hyperreactivity. The purpose of this study was to identify levels of PM 1 emitted from ice resurfacing machines used in indoor ice arenas, and to compare [PM 1] pre- and post-resurfacing to each other and to outdoor [PM 1] . Multiple one Hz measurements were recorded on 28 different days as 15-s mean of PM 1 ·cm -3 for 2 min at 1-1.5 m "above ice" in 10 rinks pre- and post-resurfacing, with measured airborne PM 1 outside each rink to be used individual rink references. Rink PM 1 ·cm -3 was ~30 times greater than PM 1 ·cm -3 outside the respective rinks (p &lt; .05). Rink values were 104.2 ± 59.3 × 10 3 PM 1 ·cm -3 during prime usage, compared to outdoor values of 3.8 ± 2.5 × 10 3 PM 1 ·cm -3. Ice resurfacing increased PM 1 ·cm -3 4-fold (p &lt; .05). No difference in PM 1 emissions between gasoline and propane powered resurfacing machines was identified. The rate of PM 1 dissipation after resurfacing was highly variable between rinks and probably dependent upon rink ventilation and resurfacing machine engine efficiency. Gas-powered edging increased PM 1 ·cm -3 18-fold and 158-fold versus pre-edging rink and outdoor values, respectively. We conclude that the primary source of airborne indoor rink PM 1 is internal combustion ice-resurfacing machines and that this poor air quality may be causal to the unique and high prevalence of airway dysfunction in ice arena athletes.</abstract><cop>England</cop><pub>Informa UK Ltd</pub><pmid>12579455</pmid><doi>10.1080/08958370304502</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0895-8378
ispartof Inhalation toxicology, 2003-03, Vol.15 (3), p.237-250
issn 0895-8378
1091-7691
language eng
recordid cdi_proquest_miscellaneous_16163172
source Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list)
subjects Air Pollutants - analysis
Air Pollution, Indoor - analysis
Bronchial Hyperreactivity - etiology
Environmental Illness - etiology
Particle Size
Skating
Vehicle Emissions - analysis
title High Levels of Airborne Ultrafine and Fine Particulate Matter in Indoor Ice Arenas
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T18%3A42%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20Levels%20of%20Airborne%20Ultrafine%20and%20Fine%20Particulate%20Matter%20in%20Indoor%20Ice%20Arenas&rft.jtitle=Inhalation%20toxicology&rft.au=Rundell,%20Kenneth%20W.&rft.date=2003-03-01&rft.volume=15&rft.issue=3&rft.spage=237&rft.epage=250&rft.pages=237-250&rft.issn=0895-8378&rft.eissn=1091-7691&rft_id=info:doi/10.1080/08958370304502&rft_dat=%3Cproquest_infor%3E16163172%3C/proquest_infor%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c518t-20fb3f472f7cdab0aa02d9b2fdbd8129a1f4ba870d6f3e9c9be2d31cbc4262943%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=14652073&rft_id=info:pmid/12579455&rfr_iscdi=true