Loading…

Test beam results of heavily irradiated magnetic Czochralski silicon (MCz-Si) strip detectors

Strip detectors with an area of 16 cm 2 were processed on high resistivity n-type magnetic Czochralski silicon. In addition, detectors were processed on high resistivity Float Zone wafers with the same mask set for comparison. The detectors were irradiated to several different fluences up to the flu...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2010-01, Vol.612 (3), p.497-500
Main Authors: Luukka, P., Härkünen, J., Mäenpää, T., Betchart, B., Bhattacharya, S., Czellar, S., Demina, R., Dierlamm, A., Gotra, Y., Frey, M., Hartmann, F., Karimäki, V., Keutgen, T., Korjenevski, S., Kortelainen, M.J., Lampén, T., Lemaitre, V., Maksimow, M., Militaru, O., Moilanen, H., Neuland, M., Simonis, H.J., Spiegel, L., Tuominen, E., Tuominiemi, J., Tuovinen, E., Viljanen, H.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Strip detectors with an area of 16 cm 2 were processed on high resistivity n-type magnetic Czochralski silicon. In addition, detectors were processed on high resistivity Float Zone wafers with the same mask set for comparison. The detectors were irradiated to several different fluences up to the fluence of 3 × 10 15 1 MeV n eq / cm 2 with protons or with mixed protons and neutrons. The detectors were fully characterized with CV- and IV-measurements prior to and after the irradiation. The beam test was carried out at the CERN H2 beam line using a silicon beam telescope that determines the tracks of the incoming particles and hence provides a reference measurement for the detector characterization. The n-type MCz-Si strip detectors have an acceptable S/N at least up to the fluence of 1 × 10 15 n eq / cm 2 and thus, they are a feasible option for the strip detector layers in the SLHC tracking systems.
ISSN:0168-9002
1872-9576