Loading…
Assessment of registration accuracy during computer-aided oncologic limb-salvage surgery
Purpose Computer-aided surgery is used in musculoskeletal tumor procedures to improve the surgeon’s orientation to local anatomy during tumor resection. For the navigation system to function correctly, preoperative imaging (e.g., CT, MR) must be registered to the patient in the operating room. The g...
Saved in:
Published in: | International journal for computer assisted radiology and surgery 2015-09, Vol.10 (9), p.1469-1475 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
Computer-aided surgery is used in musculoskeletal tumor procedures to improve the surgeon’s orientation to local anatomy during tumor resection. For the navigation system to function correctly, preoperative imaging (e.g., CT, MR) must be registered to the patient in the operating room. The goals of this study were (1) to directly quantify registration accuracy in computer-aided tumor surgery and (2) to validate the “system reported error” (SRE) of the navigation system.
Methods
Registration accuracy was evaluated in eight bone sarcoma cases by determining the location of the anatomical paired-points used for registration following surface matching. Coordinates of specific intraoperative post-registration points were compared with the corresponding coordinates in preoperative CT scans to determine the measurement error (ME).
Results
The mean difference between post-registration points and planned registration points was
12.21
±
6.52
mm
, significantly higher than the mean SRE (
0.68
±
0.15
mm
;
p
=
0.002
; 95 % CI 6.11–16.96 mm). The SRE poorly correlated with the calculated ME (
R
2
=
0.040
). Anatomical paired-point registration with surface matching results in a substantial shift in the post-registration coordinates of the same paired-points used for registration, and this shift is not represented by the SRE.
Conclusion
The SRE of a surgical navigation system was poorly correlated with direct measurements obtained in musculoskeletal tumor surgery. Improvement in registration accuracy is needed to better navigate tumor boundaries and ensure clear margins while maximally preserving the unaffected tissues and reducing operative morbidity. |
---|---|
ISSN: | 1861-6410 1861-6429 |
DOI: | 10.1007/s11548-014-1146-1 |