A concordance study of the Altona RealStar Varicella‐Zoster virus real‐time quantitative PCR and in‐house conventional qualitative PCR

This study compared the Altona RealStar™ VZV Kit 1.0 real time quantitative VZV PCR with in‐house qualitative conventional VZV PCR on cerebrospinal fluid, mucocutaneous, and other uncommon clinical specimens. Overall, positive and negative agreement percentages were respectively 97.9% (95%CI: 93.8‐9...

Full description

Saved in:
Bibliographic Details
Published in:Journal of medical virology 2018-02, Vol.90 (2), p.334-337
Main Authors: Grandjean Lapierre, Simon, Boissinot, Karel, Renaud, Christian
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This study compared the Altona RealStar™ VZV Kit 1.0 real time quantitative VZV PCR with in‐house qualitative conventional VZV PCR on cerebrospinal fluid, mucocutaneous, and other uncommon clinical specimens. Overall, positive and negative agreement percentages were respectively 97.9% (95%CI: 93.8‐99.6), 100.0% (95%CI: 93.1‐100.0), and 96.3% (95%CI: 89.4‐99.2) while Cohen's kappa statistic value was 0.96 (95%CI: 0.91‐1.00). RealStar™ VZV quantitative PCR assay reported average quantitative viral loads of 4.4 × 105 and 1.1 × 107 copies/mL in cerebrospinal fluid and cutaneous specimens, respectively (P 