Effect of closed loop stimulation versus accelerometer on outcomes with cardiac resynchronization therapy: the CLASS trial
Purpose Chronotropic incompetence (CI) in patients with heart failure is common and associated with impaired exercise intolerance and adverse outcomes . This study sought to determine the effects of closed loop stimulation (CLS) rate-adaptive pacing on functional capacity in patients with heart fail...
Saved in:
Published in: | Journal of interventional cardiac electrophysiology 2021-09, Vol.61 (3), p.479-485 |
---|---|
Main Authors: | , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
Chronotropic incompetence (CI) in patients with heart failure is common and associated with impaired exercise intolerance and adverse outcomes
.
This study sought to determine the effects of closed loop stimulation (CLS) rate-adaptive pacing on functional capacity in patients with heart failure with reduced ejection fraction (HFrEF) and CI implanted with cardiac resynchronization therapy (CRT) devices.
Methods
A randomized, blinded, cross-over designed trial enrolled patients with HFrEF and CI implanted with a Biotronik CRT-D to complete a quality of life questionnaire, 6-min walk distance (6MWD), and cardiopulmonary exercise testing after two programmed periods: 1-week period of CLS and 1-week period of standard accelerometer (DDDR).
Results
Nine patients (6 males, mean age 71.4 years, 7 with New York Heart Association Class III, mean ejection fraction 39 ± 8%) were enrolled. Quality of life trended higher in CLS as compared to DDDR (550.8 ± 123.9 vs 489.3 ± 164.9,
p
= 0.06). There were no differences between CLS and DDDR in 6MWD (293.1 ± 90.2 m vs 315.1 ± 95.5 m,
p
= 0.52), peak heart rate (HR) 110.7 ± 14.7 bpm vs 109.7 bpm ± 14.1,
p
= 0.67), or peak VO2 (12.3 ± 4.9 ml/kg/min vs 12.9 ± 5.9,
p
= 0.47). As tests were submaximal as indicated by low respiratory exchange ratios (0.98 ± 0.11 vs 1.0 ± 0.8,
p
= 0.35), VE/VCO
2
slope also showed no difference between CLS and DDDR (35.8 ± 5.6 vs 35.4 ± 5.7,
p
= 0.65). Five patients (56%) preferred CLS programming (
p
= 1.0).
Conclusions
In patients with HFrEF and CI implanted with a CRT-D, peak HR, peak VO2, and 6MWD were equivalent, while there was a trend toward improved quality of life in CLS as compared to DDDR.
Clinical trial registration
URL:
https://www.clinicaltrials.gov
. Unique identifier: NCT02693262. |
---|---|
ISSN: | 1383-875X 1572-8595 |
DOI: | 10.1007/s10840-020-00829-4 |