Loading…

Final 5-year results of the United States Zenith Fenestrated prospective multicenter study for juxtarenal abdominal aortic aneurysms

To report 5-year results of the prospective, multicenter study designed to evaluate the Zenith Fenestrated AAA Endovascular Graft (William A. Cook Australia, Brisbane, Australia) for juxtarenal abdominal aortic aneurysms (AAAs). Sixty-seven patients (54 male, mean age 74 ± 8 years) were prospectivel...

Full description

Saved in:
Bibliographic Details
Published in:Journal of vascular surgery 2021-04, Vol.73 (4), p.1128-1138.e2
Main Authors: Oderich, Gustavo S., Farber, Mark A., Schneider, Darren, Makaroun, Michel, Sanchez, Luis A., Schanzer, Andres, Beck, Adam W., Starnes, Benjamin W., Fillinger, Mark, Tenorio, Emanuel R., Chen, Min, Zhou, Qing
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To report 5-year results of the prospective, multicenter study designed to evaluate the Zenith Fenestrated AAA Endovascular Graft (William A. Cook Australia, Brisbane, Australia) for juxtarenal abdominal aortic aneurysms (AAAs). Sixty-seven patients (54 male, mean age 74 ± 8 years) were prospectively enrolled at 14 U.S. centers from 2005 to 2012. Fenestrated stent grafts were used in patients with infrarenal aortic neck lengths of 4 to 14 mm to target 178 renal-mesenteric arteries with a mean of 2.7 vessels per patient. At 5 years, 42 of the 67 patients completed the final study follow-up, with clinical examination obtained in 41 and computed tomography imaging in 39. Outcomes adjudicated by a clinical events committee included all-cause and aneurysm-related mortality, major adverse events, renal stent occlusion/stenosis, renal function changes and renal infarcts, aneurysm sac enlargement (>5 mm), device migration (≥10 mm), type I/III endoleak, and secondary interventions. Median follow-up was 59.8 months (range, 0.1-67.5 months). There were seven deaths, including one (1.5%) within 30 days (procedure-related) and six beyond 30 days (not procedure-related in five, indeterminate in one). At 5 years, freedom from all-cause mortality was 88.8 ± 4.2% and freedom from aneurysm-related mortality was 96.8 ± 2.3%. There were no aneurysm ruptures or conversions to open surgery. Of the 129 renal arteries targeted by fenestrations, five (4%) occluded and 14 (11%) developed in-stent stenosis. Treatment included redo stenting/angioplasty in 13 vessels, renal artery bypass in 2 vessels, and failed thrombectomy in 1 vessel. Primary and secondary renal target patency was 82.7 ± 4.1% and 95.7 ± 2.1% at 5 years, respectively. Dialysis was required in one patient who had pre-existing chronic kidney disease. During the 5 years, there was 1 type IA endoleak (1.5%), 1 type IB endoleak (1.5%), 2 device migrations (3%), and 4 aneurysm sac enlargements (6%). Overall, 81% of patients had sac shrinkage at 5 years. Of 20 patients who underwent secondary interventions, 12 were for renal in-stent stenosis or occlusion, 7 were for endoleak, and 1 was for both indications. Freedom from secondary intervention was 63.5 ± 7.2% at 5 years. These 5-year results confirm the safety and effectiveness of the Zenith Fenestrated AAA stent graft with no late graft- or aneurysm-related deaths. In-stent stenosis of bare metal renal stents was the most frequent indication for secondary intervention. Th
ISSN:0741-5214
1097-6809
DOI:10.1016/j.jvs.2020.08.128