Loading…

Impact of Cryoballoon Ablation on Electrophysiology Lab Efficiency During the Treatment of Patients With Persistent Atrial Fibrillation: A Subanalysis of the STOP Persistent AF Study

The volume of atrial fibrillation (AF) catheter ablation procedures has increased to address the growing patient population with AF; however, the impact of cryoballoon ablation on electrophysiology (EP) lab throughput is under-studied when treating patients with persistent AF (PsAF). To assess EP la...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of invasive cardiology 2021-07, Vol.33 (7), p.E522
Main Authors: Kowalski, Marcin, Su, Wilber W, Holbrook, Reece, Sale, Alicia, Braegelmann, Kendra M, Calkins, Hugh
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The volume of atrial fibrillation (AF) catheter ablation procedures has increased to address the growing patient population with AF; however, the impact of cryoballoon ablation on electrophysiology (EP) lab throughput is under-studied when treating patients with persistent AF (PsAF). To assess EP lab utilization associated with cryoballoon ablation for the treatment of patients with PsAF and to evaluate mechanisms that optimize hospital resources. Procedural data derived from the STOP Persistent AF trial were input into a discrete event simulation to assess EP lab utilization during AF ablation procedures. Patient and physician delays and lab occupancy times were modeled in a nominal and efficient EP lab setting over 1000 days. Accounting for variation in procedural times, we evaluated the number of days in which preplanned pulmonary vein isolation (PVI) cases resulted in overtime or excess time for non-ablation EP cases within a given lab day. A sensitivity analysis determined the parameters that most strongly influenced EP lab throughput. Lab occupancy times for the Nominal Use (NU) case included 165 procedures, and the High-Efficiency Use (HEU) case was derived from 69 procedures conducted at sites with faster procedure times than average. The HEU case had shorter lab occupancy times than the NU case (158 ± 32 minutes vs 188 ± 51 minutes, respectively). In the NU case, a total of 2000 procedures were conducted, with 28 lab days (2.8%) extending into overtime and 900 lab days (90%) exhibiting excess time for a non-ablation EP case. In the HEU case, a total of 3000 procedures were conducted, with 87 lab days (8.7%) extending into overtime and 635 lab days (63.5%) exhibiting excess time for a non-ablation EP case. The model was most sensitive to lab occupancy duration and the time of day that overtime started. Cryoballoon ablation for the treatment of patients with PsAF confers EP lab efficiencies that can support 3 PVI cases in a lab day.
ISSN:1557-2501
1557-2501
DOI:10.25270/jic/20.00620