Loading…
Machine Learning-Enabled NIR Spectroscopy in Assessing Powder Blend Uniformity: Clear-Up Disparities and Biases Induced by Physical Artefacts
NIR spectroscopy is a non-destructive characterization tool for the blend uniformity (BU) assessment. However, NIR spectra of powder blends often contain overlapping physical and chemical information of the samples. Deconvoluting the information related to chemical properties from that associated wi...
Saved in:
Published in: | AAPS PharmSciTech 2022-10, Vol.23 (7), p.277-277, Article 277 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | NIR spectroscopy is a non-destructive characterization tool for the blend uniformity (BU) assessment. However, NIR spectra of powder blends often contain overlapping physical and chemical information of the samples. Deconvoluting the information related to chemical properties from that associated with the physical effects is one of the major objectives of this work. We achieve this aim in two ways. Firstly, we identified various sources of variability that might affect the BU results. Secondly, we leverage the machine learning-based sophisticated data analytics processes. To accomplish the aforementioned objectives, calibration samples of amlodipine as an active pharmaceutical ingredient (API) with the concentrations ranging between 67 and 133% w/w (dose ~ 3.6% w/w), in powder blends containing excipients, were prepared using a gravimetric approach and assessed using NIR spectroscopic analysis, followed by HPLC measurements. The bias in NIR results was investigated by employing data quality metrics (DQM) and bias-variance decomposition (BVD). To overcome the bias, the clustered regression (non-parametric and linear) was applied. We assessed the model’s performance by employing the hold-out and k-fold internal cross-validation (CV). NIR-based blend homogeneity with low mean absolute error and an interval estimates of 0.674 (mean) ± 0.218 (standard deviation) w/w was established. Additionally, bootstrapping-based CV was leveraged as part of the NIR method lifecycle management that demonstrated the mean absolute error (MAE) of BU ± 3.5% w/w and BU ± 1.5% w/w for model generalizability and model transferability, respectively. A workflow integrating machine learning to NIR spectral analysis was established and implemented.
Graphical Abstract
Impact of various data learning approaches on NIR spectral data |
---|---|
ISSN: | 1530-9932 1530-9932 |
DOI: | 10.1208/s12249-022-02403-9 |