Evaluating femoral graft placement using three-dimensional magnetic resonance imaging in the reconstruction of the anterior cruciate ligament via independent or transtibial drilling techniques: a retrospective cohort study
Purpose Anterior cruciate ligament (ACL) reconstruction is a common surgical procedure, yet failure still largely occurs due to nonanatomically positioned grafts. The purpose of this study was to retrospectively evaluate patients with torn ACLs before and after reconstruction via 3D MRI and thereby...
Saved in:
Published in: | European journal of orthopaedic surgery & traumatology 2024-04, Vol.34 (3), p.1297-1306 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
Anterior cruciate ligament (ACL) reconstruction is a common surgical procedure, yet failure still largely occurs due to nonanatomically positioned grafts. The purpose of this study was to retrospectively evaluate patients with torn ACLs before and after reconstruction via 3D MRI and thereby assess the accuracy of graft position on the femoral condyle.
Methods
Forty-one patients with unilateral ACL tears were recruited. Each patient underwent 3D MRI of both knees before and after surgery. The location of the reconstructed femoral footprint relative to the patient’s native footprint was compared.
Results
Native ACL anatomical location of the native ACL had a significant impact on graft position. Native ACLs that were previously more anterior yielded grafts that were more posterior (3.70 ± 1.22 mm,
P
= 0.00018), and native ACL that were previously more proximal yielded grafts that were more distal (3.25 ± 1.09 mm,
P
= 0.0042). Surgeons using an independent drilling method positioned 76.2% posteriorly relative to the native location, with a mean 0.1 ± 2.8 mm proximal (
P
= 0.8362) and 1.8 ± 3.0 mm posterior (
P
= 0.0165). Surgeons using a transtibial method positioned 75% proximal relative to the native location, with a mean 2.2 ± 3.0 mm proximal (
P
= 0.0042) and 0.2 ± 2.6 mm posterior (
P
= 0.8007). These two techniques showed a significant difference in magnitude in the distal–proximal axis (
P
= 0.0332).
Conclusion
The femoral footprint position differed between the native and reconstructed ACLs, suggesting that ACL reconstructions are not accurate. Rather, they are converging to a normative reference point that is neither anatomical nor isometric. |
---|---|