Loading…

Are the Chicago 3.0 manometric diagnostics consistent with Chicago 4.0?

There is little information on the degree of concordance between the results obtained using the Chicago 3.0 (CCv3.0) and Chicago 4.0 (CCv4.0) protocols to interpret high-resolution manometry (HRM) seeking to determine the value provided by the new swallowing maneuvers included in the last protocol....

Full description

Saved in:
Bibliographic Details
Published in:Diseases of the esophagus 2024-04, Vol.37 (4)
Main Authors: Tobón, Angélica, Hani, Albis C, Pulgarin, Cristiam D, Ardila, Andres F, Muñoz, Oscar M, Sierra, Julian A, Cisternas, Daniel
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:There is little information on the degree of concordance between the results obtained using the Chicago 3.0 (CCv3.0) and Chicago 4.0 (CCv4.0) protocols to interpret high-resolution manometry (HRM) seeking to determine the value provided by the new swallowing maneuvers included in the last protocol. This is a study of diagnostic tests, evaluating concordance by consistency between the results obtained by the CCv3.0 and CCv4.0 protocols, in patients undergoing HRM. Concordance was assessed with the kappa test. Bland-Altman scatter plots, and Lin's correlation-concordance coefficient (CCC) were used to assess the agreement between IRP measured with swallows in the supine and seated position or with solid swallows. One hundred thirty-two patients were included (65% women, age 53 ± 17 years). The most frequent HRM indication was dysphagia (46.1%). Type I was the most common type of gastroesophageal junction. The most frequent CCv4.0 diagnoses were normal esophageal motility (68.9%), achalasia (15.5%), and ineffective esophageal motility (IEM; 5.3%). The agreement between the results was substantial (Kappa 0.77 ± 0.05), with a total agreement of 87.9%. Diagnostic reclassification occurred in 12.1%, from IEM in CCv3.0 to normal esophageal motility in CCv4.0. Similarly, there was a high level of agreement between the IRP measured in the supine compared to the seated position (CCC0.92) and with solid swallows (CCC0.96). In conclusion, the CCv4.0 protocol presents a high concordance compared to CCv3.0. In the majority of manometric diagnoses there is no reclassification of patients with provocation tests. However, the more restrictive criteria of CCv4.0 achieve a better reclassification of patients with IEM.
ISSN:1120-8694
1442-2050
DOI:10.1093/dote/doad071