Loading…

Enhancing gas chromatography-mass spectrometry resolution and pure analyte discovery using intra-chromatogram elution profile matching

Chemometric decomposition methods like multivariate curve resolution-alternating least squares (MCR-ALS) are often employed in gas chromatography-mass spectrometry (GC-MS) to improve analyte identification and quantitation. However, these methods can perform poorly for analytes with a low chromatogr...

Full description

Saved in:
Bibliographic Details
Published in:Talanta (Oxford) 2024-10, Vol.278, p.126453, Article 126453
Main Authors: Cain, Caitlin N., Synovec, Robert E.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Chemometric decomposition methods like multivariate curve resolution-alternating least squares (MCR-ALS) are often employed in gas chromatography-mass spectrometry (GC-MS) to improve analyte identification and quantitation. However, these methods can perform poorly for analytes with a low chromatographic resolution (Rs) and a high degree of spectral contamination from noise and background interferences. Thus, we propose a novel computational algorithm, termed mzCompare, to improve analyte identification and quantitation when coupled to MCR-ALS. The mzCompare method utilizes an underlying requirement that the retention time and peak shape between mass channels (m/z) of the same analyte should be similar. By discovering the selective m/z for a given analyte in a chromatogram, a pure elution profile can be generated and used as an equality constraint in MCR-ALS. The performance of the mzCompare methodology is demonstrated with both experimental and simulated chromatograms. Experimentally, unresolved analytes with a Rs as low as 0.05 could be confidently identified with mzCompare assisted MCR-ALS. Furthermore, application of the mzCompare algorithm to a complex aerospace fuel resulted in the discovery of 335 analytes, a 44 % increase compared to conventional peak detection methods. GC-MS simulations of target-interferent analyte pairs demonstrated that the performance of MCR-ALS deteriorated below a Rs of ∼0.25. However, mzCompare assisted MCR-ALS showed excellent identification and acceptable quantitative accuracy at a Rs of ∼0.02. These results show that the mzCompare algorithm can help analysts overcome modeling ambiguities resulting from the chemometric multiplex disadvantage. [Display omitted] •A new algorithm for pure analyte discovery is established for GC-MS chromatograms.•This method is successful under severe situations of chromatographic overlap.•The outputs can enhance mass spectrum purification and quantitation efforts.•The benefits of this algorithm are demonstrated with experimental and simulated GC-MS data.
ISSN:0039-9140
1873-3573
1873-3573
DOI:10.1016/j.talanta.2024.126453