Loading…
Delays and errors in cardiopulmonary resuscitation and defibrillation by pediatric residents during simulated cardiopulmonary arrests
Abstract Background The quality of life support delivered during cardiopulmonary resuscitation affects outcomes. However, little data exist regarding the quality of resuscitation delivered to children and factors associated with adherence to American Heart Association (AHA) resuscitation guidelines....
Saved in:
Published in: | Resuscitation 2009-07, Vol.80 (7), p.819-825 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract Background The quality of life support delivered during cardiopulmonary resuscitation affects outcomes. However, little data exist regarding the quality of resuscitation delivered to children and factors associated with adherence to American Heart Association (AHA) resuscitation guidelines. Participants Pediatric residents from an academic, tertiary care hospital. Design Prospective, observational cohort study of residents trained in the AHA PALS 2000 guidelines managing a high-fidelity mannequin simulator programmed to develop pulseless ventricular tachycardia (PVT). Main outcome measures Proportion of residents who: (1) started compressions in ≤1 min from onset of PVT, (2) defibrillated in ≤3 min and (3) factors associated with time to defibrillation. Results Seventy of eighty (88%) residents participated. Forty-six of seventy (66%) failed to start compressions within 1 min of pulselessness and 23/70 (33%) never started compressions. Only 38/70 (54%) residents defibrillated the mannequin in ≤3 min of onset of PVT. There was no significant difference in time elapsed between onset of PVT and defibrillation by level of post-graduate training. However, residents who had previously discharged a defibrillator on either a patient or a simulator compared to those who had not were 87% more likely to successfully defibrillate the mannequin at any point in time (hazard ratio 1.87, 95% CI: 1.08–3.21, p = 0.02). Conclusions Pediatric residents do not meet performance standards set by the AHA. Future curricula should focus training on identified defects including: (1) equal emphasis on “airway and breathing” and “circulation” and (2) hands-on training with using and discharging a defibrillator in order to improve safety and outcomes. |
---|---|
ISSN: | 0300-9572 1873-1570 |
DOI: | 10.1016/j.resuscitation.2009.03.020 |