Loading…
High rate of adverse events following circumcision of young male adults with the Tara KLamp technique : A randomised trial in South Africa
The Tara KLamp (TK) device has been claimed to enable circumcisions to be performed safely and easily in medical and non-medical environments. Published evaluation studies have been conducted among young children only. Following a randomised controlled trial (RCT) on 3 274 participants on the impact...
Saved in:
Published in: | South African medical journal 2009-03, Vol.99 (3), p.163-169 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The Tara KLamp (TK) device has been claimed to enable circumcisions to be performed safely and easily in medical and non-medical environments. Published evaluation studies have been conducted among young children only.
Following a randomised controlled trial (RCT) on 3 274 participants on the impact of male circumcision on HIV transmission, 69 control group members participated in this male circumcision methods trial and were randomised to a forceps-guided (FG) group and a TK group, and circumcised.
Of the 166 men asked to participate, 97 declined, most (94) refusing circumcision by the TK technique; 34 men were randomised to the FG group and 35 to the TK group, and 32 and 24 patients were circumcised by the FG and TK methods respectively, of whom 29 and 19 respectively attended the post-circumcision visit. All 12 adverse event sheets corresponded to the TK group (p |
---|---|
ISSN: | 0256-9574 |