Precision of micellar electrokinetic capillary chromatography in the determination of seven antibiotics in pharmaceuticals and feedstuffs
Validation of analytical procedures is important for their efficient and reliable application. The International Conference on Harmonisation (ICH), Food and Drug Administration (FDA) and pharmacopoeia guidelines achieved a great deal in harmonising the definitions of the required validation characte...
Saved in:
Published in: | Analytica chimica acta 2007-06, Vol.594 (1), p.119-127 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c412t-586a4200d092e3a1e09ba8bf8cfdb711303df9d356fb3704d12982d934201b1c3 |
---|---|
cites | cdi_FETCH-LOGICAL-c412t-586a4200d092e3a1e09ba8bf8cfdb711303df9d356fb3704d12982d934201b1c3 |
container_end_page | 127 |
container_issue | 1 |
container_start_page | 119 |
container_title | Analytica chimica acta |
container_volume | 594 |
creator | Injac, Rade Kocevar, Nina Kreft, Samo |
description | Validation of analytical procedures is important for their efficient and reliable application. The International Conference on Harmonisation (ICH), Food and Drug Administration (FDA) and pharmacopoeia guidelines achieved a great deal in harmonising the definitions of the required validation characteristics. It is well known that poor reproducibility limits the practical implementation of capillary electrophoresis (CE). A precision study on four different MEKC methods was performed with 11 samples, containing seven antibiotics, by two analysts, in few days, on two capillary electrophoresis instruments. Five pharmaceutical preparations and three animal feeds were used. Precision was statistically analysed using migration time, peak area and height of each compound, as well as electroosmotic front (EOF). In 25 of 31 cases, the reproducibility of peak area, peak height and migration time was good ( |
doi_str_mv | 10.1016/j.aca.2007.05.003 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_70609899</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S000326700700863X</els_id><sourcerecordid>70609899</sourcerecordid><originalsourceid>FETCH-LOGICAL-c412t-586a4200d092e3a1e09ba8bf8cfdb711303df9d356fb3704d12982d934201b1c3</originalsourceid><addsrcrecordid>eNqFkc9u1DAQxi0EotvCA3BBvsAty9jOP4sTqgpFqgQHOFuOPWa9bOJgO5X6CLw1DhupNzhZ_uY3n2bmI-QVgz0D1r477rXRew7Q7aHZA4gnZMf6TlS14PVTsoMiVbzt4IJcpnQsX86gfk4uWNe0IKTYkd9fIxqffJhocHT0Bk8nHSme0OQYfvoJszfU6Nmv-gM1hxhGncOPqOfDA_UTzQekFjPG0U86b0YJ73Giesp-8KE4pJWcDzqO2uBSBH1KpWypQ7QpL86lF-SZKyq-3N4r8v3jzbfr2-ruy6fP1x_uKlMznqumb3VdVrYgOQrNEOSg-8H1xtmhY0yAsE5a0bRuEB3UlnHZcytFaWIDM-KKvD37zjH8WjBlNfr0d-0Jw5JUBy3IXsr_glzKvuWyLiA7gyaGlCI6NUc_lmspBmoNSh1VCUqtQSloVEml9LzezJdhRPvYsSVTgDcboFO5lot6Kjk9cn3PuYB1yvdnDsvN7j1GlYzHyaD1JdmsbPD_GOMP5hGzKQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29986294</pqid></control><display><type>article</type><title>Precision of micellar electrokinetic capillary chromatography in the determination of seven antibiotics in pharmaceuticals and feedstuffs</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Injac, Rade ; Kocevar, Nina ; Kreft, Samo</creator><creatorcontrib>Injac, Rade ; Kocevar, Nina ; Kreft, Samo</creatorcontrib><description>Validation of analytical procedures is important for their efficient and reliable application. The International Conference on Harmonisation (ICH), Food and Drug Administration (FDA) and pharmacopoeia guidelines achieved a great deal in harmonising the definitions of the required validation characteristics. It is well known that poor reproducibility limits the practical implementation of capillary electrophoresis (CE). A precision study on four different MEKC methods was performed with 11 samples, containing seven antibiotics, by two analysts, in few days, on two capillary electrophoresis instruments. Five pharmaceutical preparations and three animal feeds were used. Precision was statistically analysed using migration time, peak area and height of each compound, as well as electroosmotic front (EOF). In 25 of 31 cases, the reproducibility of peak area, peak height and migration time was good (<5%). In most cases the reproducibility of peak area was much better than the reproducibility of peak height. The worst reproducibility that we observed was 12.7% for peak height and 7.6% for peak area.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2007.05.003</identifier><identifier>PMID: 17560393</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Animal Feed - analysis ; Anti-Bacterial Agents - analysis ; Antibiotics ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Chromatography, Micellar Electrokinetic Capillary - methods ; Exact sciences and technology ; Feedstuffes ; General, instrumentation ; Micellar electrokinetic capillary chromatography ; Other chromatographic methods ; Pharmaceutical Preparations - chemistry ; Pharmaceuticals ; Precision ; Reproducibility of Results ; Software</subject><ispartof>Analytica chimica acta, 2007-06, Vol.594 (1), p.119-127</ispartof><rights>2007 Elsevier B.V.</rights><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c412t-586a4200d092e3a1e09ba8bf8cfdb711303df9d356fb3704d12982d934201b1c3</citedby><cites>FETCH-LOGICAL-c412t-586a4200d092e3a1e09ba8bf8cfdb711303df9d356fb3704d12982d934201b1c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=18822309$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17560393$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Injac, Rade</creatorcontrib><creatorcontrib>Kocevar, Nina</creatorcontrib><creatorcontrib>Kreft, Samo</creatorcontrib><title>Precision of micellar electrokinetic capillary chromatography in the determination of seven antibiotics in pharmaceuticals and feedstuffs</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>Validation of analytical procedures is important for their efficient and reliable application. The International Conference on Harmonisation (ICH), Food and Drug Administration (FDA) and pharmacopoeia guidelines achieved a great deal in harmonising the definitions of the required validation characteristics. It is well known that poor reproducibility limits the practical implementation of capillary electrophoresis (CE). A precision study on four different MEKC methods was performed with 11 samples, containing seven antibiotics, by two analysts, in few days, on two capillary electrophoresis instruments. Five pharmaceutical preparations and three animal feeds were used. Precision was statistically analysed using migration time, peak area and height of each compound, as well as electroosmotic front (EOF). In 25 of 31 cases, the reproducibility of peak area, peak height and migration time was good (<5%). In most cases the reproducibility of peak area was much better than the reproducibility of peak height. The worst reproducibility that we observed was 12.7% for peak height and 7.6% for peak area.</description><subject>Analytical chemistry</subject><subject>Animal Feed - analysis</subject><subject>Anti-Bacterial Agents - analysis</subject><subject>Antibiotics</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Chromatography, Micellar Electrokinetic Capillary - methods</subject><subject>Exact sciences and technology</subject><subject>Feedstuffes</subject><subject>General, instrumentation</subject><subject>Micellar electrokinetic capillary chromatography</subject><subject>Other chromatographic methods</subject><subject>Pharmaceutical Preparations - chemistry</subject><subject>Pharmaceuticals</subject><subject>Precision</subject><subject>Reproducibility of Results</subject><subject>Software</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkc9u1DAQxi0EotvCA3BBvsAty9jOP4sTqgpFqgQHOFuOPWa9bOJgO5X6CLw1DhupNzhZ_uY3n2bmI-QVgz0D1r477rXRew7Q7aHZA4gnZMf6TlS14PVTsoMiVbzt4IJcpnQsX86gfk4uWNe0IKTYkd9fIxqffJhocHT0Bk8nHSme0OQYfvoJszfU6Nmv-gM1hxhGncOPqOfDA_UTzQekFjPG0U86b0YJ73Giesp-8KE4pJWcDzqO2uBSBH1KpWypQ7QpL86lF-SZKyq-3N4r8v3jzbfr2-ruy6fP1x_uKlMznqumb3VdVrYgOQrNEOSg-8H1xtmhY0yAsE5a0bRuEB3UlnHZcytFaWIDM-KKvD37zjH8WjBlNfr0d-0Jw5JUBy3IXsr_glzKvuWyLiA7gyaGlCI6NUc_lmspBmoNSh1VCUqtQSloVEml9LzezJdhRPvYsSVTgDcboFO5lot6Kjk9cn3PuYB1yvdnDsvN7j1GlYzHyaD1JdmsbPD_GOMP5hGzKQ</recordid><startdate>20070626</startdate><enddate>20070626</enddate><creator>Injac, Rade</creator><creator>Kocevar, Nina</creator><creator>Kreft, Samo</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20070626</creationdate><title>Precision of micellar electrokinetic capillary chromatography in the determination of seven antibiotics in pharmaceuticals and feedstuffs</title><author>Injac, Rade ; Kocevar, Nina ; Kreft, Samo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c412t-586a4200d092e3a1e09ba8bf8cfdb711303df9d356fb3704d12982d934201b1c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Analytical chemistry</topic><topic>Animal Feed - analysis</topic><topic>Anti-Bacterial Agents - analysis</topic><topic>Antibiotics</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Chromatography, Micellar Electrokinetic Capillary - methods</topic><topic>Exact sciences and technology</topic><topic>Feedstuffes</topic><topic>General, instrumentation</topic><topic>Micellar electrokinetic capillary chromatography</topic><topic>Other chromatographic methods</topic><topic>Pharmaceutical Preparations - chemistry</topic><topic>Pharmaceuticals</topic><topic>Precision</topic><topic>Reproducibility of Results</topic><topic>Software</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Injac, Rade</creatorcontrib><creatorcontrib>Kocevar, Nina</creatorcontrib><creatorcontrib>Kreft, Samo</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Injac, Rade</au><au>Kocevar, Nina</au><au>Kreft, Samo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Precision of micellar electrokinetic capillary chromatography in the determination of seven antibiotics in pharmaceuticals and feedstuffs</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2007-06-26</date><risdate>2007</risdate><volume>594</volume><issue>1</issue><spage>119</spage><epage>127</epage><pages>119-127</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>Validation of analytical procedures is important for their efficient and reliable application. The International Conference on Harmonisation (ICH), Food and Drug Administration (FDA) and pharmacopoeia guidelines achieved a great deal in harmonising the definitions of the required validation characteristics. It is well known that poor reproducibility limits the practical implementation of capillary electrophoresis (CE). A precision study on four different MEKC methods was performed with 11 samples, containing seven antibiotics, by two analysts, in few days, on two capillary electrophoresis instruments. Five pharmaceutical preparations and three animal feeds were used. Precision was statistically analysed using migration time, peak area and height of each compound, as well as electroosmotic front (EOF). In 25 of 31 cases, the reproducibility of peak area, peak height and migration time was good (<5%). In most cases the reproducibility of peak area was much better than the reproducibility of peak height. The worst reproducibility that we observed was 12.7% for peak height and 7.6% for peak area.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>17560393</pmid><doi>10.1016/j.aca.2007.05.003</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2670 |
ispartof | Analytica chimica acta, 2007-06, Vol.594 (1), p.119-127 |
issn | 0003-2670 1873-4324 |
language | eng |
recordid | cdi_proquest_miscellaneous_70609899 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Analytical chemistry Animal Feed - analysis Anti-Bacterial Agents - analysis Antibiotics Chemistry Chromatographic methods and physical methods associated with chromatography Chromatography, Micellar Electrokinetic Capillary - methods Exact sciences and technology Feedstuffes General, instrumentation Micellar electrokinetic capillary chromatography Other chromatographic methods Pharmaceutical Preparations - chemistry Pharmaceuticals Precision Reproducibility of Results Software |
title | Precision of micellar electrokinetic capillary chromatography in the determination of seven antibiotics in pharmaceuticals and feedstuffs |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T14%3A14%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Precision%20of%20micellar%20electrokinetic%20capillary%20chromatography%20in%20the%20determination%20of%20seven%20antibiotics%20in%20pharmaceuticals%20and%20feedstuffs&rft.jtitle=Analytica%20chimica%20acta&rft.au=Injac,%20Rade&rft.date=2007-06-26&rft.volume=594&rft.issue=1&rft.spage=119&rft.epage=127&rft.pages=119-127&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/j.aca.2007.05.003&rft_dat=%3Cproquest_cross%3E70609899%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c412t-586a4200d092e3a1e09ba8bf8cfdb711303df9d356fb3704d12982d934201b1c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=29986294&rft_id=info:pmid/17560393&rfr_iscdi=true |