Loading…
Atrial overdrive pacing and incidence of heart failure-related adverse events in permanently paced patients
Atrial overdrive pacing algorithms may be effective in preventing or suppressing atrial fibrillation (AF). However, the maintenance of a heart rate incessantly faster than spontaneous could induce left ventricular (LV) dysfunction and promote heart failure (HF) on the long term. This post hoc analys...
Saved in:
Published in: | Journal of interventional cardiac electrophysiology 2007-06, Vol.19 (1), p.55-60 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Atrial overdrive pacing algorithms may be effective in preventing or suppressing atrial fibrillation (AF). However, the maintenance of a heart rate incessantly faster than spontaneous could induce left ventricular (LV) dysfunction and promote heart failure (HF) on the long term.
This post hoc analysis examined the effects of a new overdrive algorithm on the incidence of HF-related adverse events in 411 patients enrolled in the ADOPT-A trial.
The AF Suppression algorithm was randomly programmed ON in 209 patients (treatment group) versus OFF in 202 patients (control group). The incidence of HF-related adverse events and HF-related deaths over a 6-month follow-up was compared between the two groups. Patients with versus without HF-related clinical events were also compared to each other within each group.
There were eight HF-related adverse clinical events (3.8%) in the treatment group and 11 (5.4%) in the control group, including four HF-related deaths (1.9 vs. 2.0%) in each group during follow-up. Baseline NYHA functional class in patients with versus without HF-related adverse events was 1.4 +/- 0.5 versus 1.5 +/- 0.7 in the control, and 1.5 +/- 0.8 versus 1.5 +/- 0.6 in the treatment group. LV ejection fraction (EF) was 49 +/- 7% in patients with, versus 57 +/- 12% in patients without HF-related adverse events, in the control group, and 43 +/- 14% in patients with, versus 56 +/- 13% in patients without HF-related adverse events, in the treatment group. LVEF was lowest and similar in both groups among patients who died from HF (35 +/- 10% in the control and 38 +/- 27% in the treatment group).
In ADOPT-A, HF-related clinical events and deaths were related to LV dysfunction and not to atrial pacing overdriven by the AF suppression algorithm. |
---|---|
ISSN: | 1383-875X 1572-8595 |