Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination

To evaluate the performance of two different continuous cardiac output monitoring systems based on the thermodilution principle in critically ill patients. Nineteen cardiac surgical patients were randomly assigned to continuous cardiac output monitoring using one of the two systems under study (grou...

Full description

Saved in:
Bibliographic Details
Published in:Canadian journal of anesthesia 2001-12, Vol.48 (11), p.1143-1147
Main Authors: ZÖLLNER, Christian, GOETZ, Alwin E, WEIS, Marion, MÖRSTEDT, Karl, PICHLER, Bodo, LAMM, Peter, KILGER, Erich, HALLER, Mathias
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To evaluate the performance of two different continuous cardiac output monitoring systems based on the thermodilution principle in critically ill patients. Nineteen cardiac surgical patients were randomly assigned to continuous cardiac output monitoring using one of the two systems under study (group I, IntelliCath(TM) catheter, n=9; group II, Opti-Q(TM) catheter, n=10). Each patient was studied over a period of three hours. Conventional bolus thermodilution cardiac output measurements were carried out every 15 min leading to 13 measurements in each patient. The continuous cardiac output values were compared with the bolus thermodilution measurements. Bias (mean difference between continuous and bolus thermodilution) and precision (SD of differences) were calculated as a measure of agreement between the respective continuous method and conventional bolus thermodilution. The range of measured cardiac outputs was 3.8-15.4 L*min(-1) (IntelliCath(TM)) and 3.5-8.3 L*min(-1) (OptiQ(TM)). Bias and precision was 0.06 +/- 0.76 L*min(-1) (IntelliCath(TM)) and -0.04 +/- 0.74 L*min(-1) (OptiQ(TM)), respectively. There was no difference in bias between the two systems (P=0.38). +/- 2 SD of the differences (i.e., 95% of the differences) did not fall within the predetermined limits of agreement of +/- 0.5 L*min(-1). There was no difference between the two systems regarding the agreement with conventional bolus thermodilution as the standard. A discrepancy between bolus and continuous thermodilution cardiac output measurement techniques above the clinically acceptable limits suggest that they are not interchangeable.
ISSN:0832-610X
1496-8975
DOI:10.1007/BF03020382