Loading…

Metered-dose inhaler technique of patients in an urban ED: Prevalence of incorrect technique and attempt at education

The metered-dose inhaler (MDI) techniques of 125 asthma patients who presented to a county hospital emergency department (ED) were evaluated. Correct technique was divided into 7 steps. Twenty-one percent of the patients performed all 7 steps correctly. Mean number of steps ± SD performed correctly...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of emergency medicine 1996-07, Vol.14 (4), p.380-384
Main Authors: Shrestha, Mahesh, Parupia, M.F.Haroon, Andrews, Beth, Kim, Sang W, Martin, Tim S, Park, David I, Gee, Eddie
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The metered-dose inhaler (MDI) techniques of 125 asthma patients who presented to a county hospital emergency department (ED) were evaluated. Correct technique was divided into 7 steps. Twenty-one percent of the patients performed all 7 steps correctly. Mean number of steps ± SD performed correctly was 4.8 ± 1.7. Verbal individualized instruction was used to improve the technique of patients whose technique was less than perfect. The instruction required a mean ± SD of 8.3 ± 5.8 minutes (range, 0 to 30) for all 7 steps to be done correctly at least once. All patients were able to perform all steps correctly after instruction. The amount of time required for teaching was proportional to the number of steps performed incorrectly. The Vitalograph Aerosol Inhalation Monitor was used to verify correct patient technique and as a teaching aid with variable success. Education in proper use of the MDI is important in the overall care of the asthma patient; however, instruction requires a definite time commitment and may not be feasible for all patients in a busy ED. For some patients, alternatives that require less lengthy instruction, such as the use of breath-actuated devices, spacers, and reservoirs, may be required.
ISSN:0735-6757
1532-8171
DOI:10.1016/S0735-6757(96)90054-6