Excimer laser-induced simultaneous ablation and spectral identification of normal and atherosclerotic arterial tissue layers

A krypton-fluorine excimer laser at a 248-nm wavelength was used to irradiate normal and severely atherosclerotic segments of human postmortem femoral arteries. Single pulses and multiple pulses required for penetration or perforation of the arterial wall were applied with 16 nsec pulse width and 5...

Full description

Saved in:
Bibliographic Details
Published in:Circulation (New York, N.Y.) N.Y.), 1988-10, Vol.78 (4), p.1031-1039
Main Authors: LAUFER, G, WOLLENEK, G, HOHLA, K, HORVAT, R, HENKE, K.-H, BUCHELT, M, WUTZL, G, WOLNER, E
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A krypton-fluorine excimer laser at a 248-nm wavelength was used to irradiate normal and severely atherosclerotic segments of human postmortem femoral arteries. Single pulses and multiple pulses required for penetration or perforation of the arterial wall were applied with 16 nsec pulse width and 5 J/cm2/pulse energy fluence. The total fluorescence of irradiated and ablated tissue was analyzed in real-time mode by means of spectroscopy. Each laser pulse produced one spectrum that was characteristic of the composition of the tissue layer, which was ablated. Fluorescence spectroscopy indicated a broad-continuum emission between 300 and 700 nm with peak fluorescence of equal intensity at wavelengths of 370 and 460 nm (ratio, 1.004 +/- 0.087) for normal media layers. Atheromas without calcification (lipid, fibrous, and mixed) were found with spectral maxima at the same wavelengths but with significantly reduced intensity at 460 nm (ratio, 1.765 +/- 0.263; p less than 0.001). In contrast to this broad-continuum fluorescence, calcified plaques displayed multiple-line emission with the most prominent peaks at wavelengths of 397, 442, 450, 461, 528, and 558 nm. These fluorescence criteria identified the histologically classified target tissue precisely. Histological examination of the corresponding arterial layers indicated sharply delineated and circumscribed tissue ablation. These results indicate that simultaneous tissue identification (diagnosis) and ablation (treatment) by excimer laser irradiation is feasible under strict laboratory conditions. We conclude that this principle demonstrates the potential for laser beam control by means of target-specific ablation.
ISSN:0009-7322
1524-4539
DOI:10.1161/01.CIR.78.4.1031