The interaction between applied peep and auto-peep during one-lung ventilation

Objective: To investigate the relationship between applied external positive end-expiratory pressure (PEEP) and auto-PEEP and the resultant total PEEP experienced by the patient during one-lung ventilation (OLV). Design: A prospective clinical study. Setting: A university hospital. Participants: Ten...

Full description

Saved in:
Bibliographic Details
Published in:Journal of cardiothoracic and vascular anesthesia 1998-04, Vol.12 (2), p.133-136
Main Authors: Slinger, Peter D., Hickey, Donald R.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective: To investigate the relationship between applied external positive end-expiratory pressure (PEEP) and auto-PEEP and the resultant total PEEP experienced by the patient during one-lung ventilation (OLV). Design: A prospective clinical study. Setting: A university hospital. Participants: Ten adult patients undergoing elective thoracotomies. Interventions: End-expiratory airway occlusion and measurement of plateau pressure during two-lung ventilation (TLV) and OLV with and without the application of 5 cm H 2O of external PEEP via the anesthetic ventilator. The effect of variation of the inspiratory-expiratory ratio on total PEEP with and without applied external PEEP was also studied. Main Results: The mean level (±SD) of auto-PEEP changing from two-lung to one-lung ventilation rose from 0.9 (±0.8) cm H 2O to 6.0 (±3.0) cm H 2O at an inspiratoryexpiratory ratio of 1: 2. The application of 5 cm H 2O external PEEP did not increase the total PEEP (7.3 ± 2.0 cm H 2O) significantly. The total PEEP increased significantly when the duration of expiration was decreased, and decreased when expiratory time increased. The change in total PEEP caused by the application of external PEEP during OLV correlated inversely with the preexisting level of auto-PEEP (r = −0.84). Conclusion: The change in end-expiratory pressure experienced by the ventilated lung during OLV when external PEEP is applied depends on the preexisting level of auto-PEEP. This may explain some of the inconsistencies in the clinical results of application of external PEEP during OLV. The total PEEP delivered to the patient should be measured whenever external PEEP is applied during OLV.
ISSN:1053-0770
1532-8422
DOI:10.1016/S1053-0770(98)90318-4