Loading…

Assessment of biomaterials as components of a reciprocating dialyser during canine dialysis

A recently reported device, the sorbent suspension reciprocating dialyser (SSRD), was investigated for use as a test system for biocompatibility of dialyser components. The device is easy to assemble and operate, and allows minimal blood contact with foreign material outside of dialyser components....

Full description

Saved in:
Bibliographic Details
Published in:Biomaterials 1984-07, Vol.5 (4), p.227-233
Main Authors: Davidson, G.W.R., Peppas, N.A., Thornhill, J.A., Ash, S.R.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A recently reported device, the sorbent suspension reciprocating dialyser (SSRD), was investigated for use as a test system for biocompatibility of dialyser components. The device is easy to assemble and operate, and allows minimal blood contact with foreign material outside of dialyser components. Its constant pressure/ variable flow rate operation allows quantification of degree of clotting of dialyser versus time. The effect of heparinization of the blood distribution gaskets (BDG) of the device on performance and dialyser lifetime was investigated. Heparin was bound to the surface of polyethylene gaskets by immersion in a solution of tridodecylmethylammonium chloride (TDMAC)-heparin complex for several hours. Gaskets were then assembled in an SSRD which was then used for experimental dialysis in dogs with AV shunts. Dialysers assembled using non-heparinized gaskets were used as controls. Blood coagulation tendency was quantified by the activated clotting time (ACT) and partial thromboplastin time (PTT), and these values correlated with the rate of clotting of the device. Heparinization of the gaskets resulted in the prevention of clotting in the dialyser until the final minutes of dialysis in all cases, in contrast to the constant decay of blood fill volume and evidence of clotting in the non-heparinized cases. However, dialyser lifetime was not significantly increased by gasket heparinization. At normal initial values of ACT (80–95 s) dialyser clotting occurred in 10–15 mia In tests with non-heparinized gaskets and systemically heparinized dogs, values obtained in the ACT test were observed to decrease during dialysis, indicating the disappearance of heparin from the blood. Both ACT and PTT tests show promise as predictors of dialyser lifetime.
ISSN:0142-9612
1878-5905
DOI:10.1016/0142-9612(84)90020-6