Loading…

Comparison of mitral valve area by pressure half-time and proximal isovelocity surface area method in patients with mitral stenosis: effect of net atrioventricular compliance

The aim of this study was to test the hypothesis that, unlike calculation of the mitral valve area (MVA) with the pressure half-time method (PHT), the proximal isovelocity surface area method (PISA) is not affected by changes in net atrioventricular compliance (C(n)). We studied 51 patients with mit...

Full description

Saved in:
Bibliographic Details
Published in:European journal of echocardiography 2011-04, Vol.12 (4), p.283-290
Main Authors: Salem Omar, Alaa Mabrouk, Tanaka, Hidekazu, AbdelDayem, Tarek Khairy, Sadek, Ayman S, Raslaan, Halah, Al-Sherbiny, Ashraf, Yamawaki, Kohei, Ryo, Keiko, Fukuda, Yuko, Norisada, Kazuko, Tatsumi, Kazuhiro, Onishi, Tetsuari, Matsumoto, Kensuke, Kawai, Hiroya, Hirata, Ken-ichi
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The aim of this study was to test the hypothesis that, unlike calculation of the mitral valve area (MVA) with the pressure half-time method (PHT), the proximal isovelocity surface area method (PISA) is not affected by changes in net atrioventricular compliance (C(n)). We studied 51 patients with mitral stenosis (MS) from two centres. MVA was assessed with the PISA (MVA(PISA)), PHT (MVA(PHT)), and planimetry (MVA(PLN), serving as the gold standard) method. C(n) was calculated with a previously validated equation using 2D echocardiography. MVA(PISA) closely correlated with MVA(PLN) (r = 0.96, P < 0.0001), while MVA(PHT) and MVA(PLN) showed a weaker but still good correlation (r = 0.69, P < 0.0001). The correlation between MVA(PHT) and MVA(PLN) for patients with C(n) between 4 and 6 mL/mmHg (considered to be normal) was excellent (r = 0.93, P < 0.0001), but that for patients with C(n) of less than 4 or more than 6 mL/mmHg was not as good (r = 0.64, P < 0.0001). Importantly, a significant inverse correlation was detected between the percentage difference among MVA(PHT), MVA(PLN), and C(n) (r = -0.77, P < 0.0001), but the line of fit was nearly flat for the percentage difference among MVA(PISA), MVA(PLN), and C(n) (r = 0.1, P = 0.388). MVA calculated with both the PISA and PHT methods correlated well with MVA calculated with the planimetry method. However, the PISA rather than PHT is recommended for patients with MS and extreme C(n) values because PISA, unlike PHT, is not affected by changes in C(n).
ISSN:1525-2167
1532-2114
DOI:10.1093/ejechocard/jeq194