Loading…

Mass transfer during Taylor flow in microchannels with and without chemical reaction

The characteristics of mass transfer from gas to liquid during Taylor flow in capillaries with diameter less than 1 mm with and without chemical reaction were investigated with Computational Fluid Dynamics modelling using 5 vol.% CO 2/N 2 mixture and 0.2 M NaOH or water as the gas and liquid phases,...

Full description

Saved in:
Bibliographic Details
Published in:Chemical engineering journal (Lausanne, Switzerland : 1996) Switzerland : 1996), 2010-06, Vol.160 (3), p.873-881
Main Authors: Shao, N., Gavriilidis, A., Angeli, P.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The characteristics of mass transfer from gas to liquid during Taylor flow in capillaries with diameter less than 1 mm with and without chemical reaction were investigated with Computational Fluid Dynamics modelling using 5 vol.% CO 2/N 2 mixture and 0.2 M NaOH or water as the gas and liquid phases, respectively. The effects on mass transfer of chemical reaction and of bubble velocity, bubble geometry and capillary size were studied. For the simulations a unit cell was used (a Taylor bubble and a liquid slug) with periodic boundary conditions at the inlet and the outlet of the unit cell, while the CO 2 concentration at the gas–liquid interface was dynamically updated to reflect the decreasing amount of CO 2 in the gas phase. The numerical model was able to predict well experimental data on the chemical absorption of CO 2 in a NaOH solution. The mass transfer performance for the various cases studied was evaluated using the CO 2 absorption fraction X% (the percentage of CO 2 transferred from the gas to the liquid phase) and the liquid utilization index Ψ (mole of CO 2 absorbed per unit volume of NaOH). Both these parameters were significantly higher in the case of chemical absorption compared to the physical one. The volumetric mass transfer coefficients, k L a, for the physical absorption were found to vary between 0.3 and 1.5 s −1 in line with literature values for Taylor flow but higher than in normal gas–liquid contactors while the specific areas achieved varied between 1000 and 10,000 m 2/m 3. Interestingly, for the conditions investigated, k L a was found to increase with channel size as did X% during physical absorption. The absorption fraction, however, increased with decreasing channel size when reaction was present. When reaction was present, CO 2 absorption was found to be enhanced between 3 and 12 times compared to physical absorption.
ISSN:1385-8947
1873-3212
DOI:10.1016/j.cej.2010.02.049