Loading…
Adaptive correction technique for 3D reconstruction of fluorescence microscopy images
Recent advances in high‐resolution imaging have provided valuable novel insights into structural relationships within cells and tissues both in vitro and in vivo. An analysis of this kind is regularly done by optical sectioning using either confocal or deconvolution microscopy. However, the reconstr...
Saved in:
Published in: | Microscopy research and technique 2008-02, Vol.71 (2), p.146-157 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Recent advances in high‐resolution imaging have provided valuable novel insights into structural relationships within cells and tissues both in vitro and in vivo. An analysis of this kind is regularly done by optical sectioning using either confocal or deconvolution microscopy. However, the reconstruction of 3D images suffers from light scattering and absorption with increasing depth by finite transparency of the used media. Photobleaching of fluorochromes has been especially troublesome and often the only remedy for loss of signal during optical sectioning is to reduce the number of sections. This causes disparities in the x–y and z dimensions of voxels, which lead to vertical distortion of the original stack of images and necessitates interpolation. Interpolation is necessary to fill up the gaps between consecutive sections in the original image stack to obtain cubic voxels. The present manuscript describes a novel method for adaptive compensation of attenuation of light intensity in stacks of fluorescence microscopy images that is based on a physical model of light attenuation. First, we use a fast interpolation technique to generate a cubic voxel‐based volume stack with the aid of a contribution look up table. With the contribution look up table, multiple calculations are avoided, which substantially reduces the computational time without compromising the accuracy of the restoration procedure. Second, each section within the resulting volume is processed to rectify its intensity values that have been altered due to photobleaching and scattering and absorption. The method allows to define the last good section in the stack and the correction is then done automatically. Microsc. Res. Tech., 2008. © 2007 Wiley‐Liss, Inc. |
---|---|
ISSN: | 1059-910X 1097-0029 |
DOI: | 10.1002/jemt.20536 |