Biological and analytical variation of the human sweating response: implications for study design and analysis

Appropriate quantification of analytical and biological variation of thermoregulatory sweating has important practical utility for research design and statistical analysis. We sought to examine contributors to variability in local forearm sweating rate (SR) and sweating onset (SO) and to evaluate th...

Full description

Saved in:
Bibliographic Details
Published in:American journal of physiology. Regulatory, integrative and comparative physiology integrative and comparative physiology, 2012-01, Vol.302 (2), p.R252-R258
Main Authors: Kenefick, Robert W, Cheuvront, Samuel N, Elliott, Leonard D, Ely, Brett R, Sawka, Michael N
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Appropriate quantification of analytical and biological variation of thermoregulatory sweating has important practical utility for research design and statistical analysis. We sought to examine contributors to variability in local forearm sweating rate (SR) and sweating onset (SO) and to evaluate the potential for using bilateral measurements. Two women and eight men (26 ± 9 yr; 79 ± 12 kg) completed 5 days of heat acclimation and walked (1.8 l/min VO(2)) on three occasions for 30 min in 40°C, 20% RH, while local SR and SO were measured. Local SR measures among days were not different (2.14 ± 0.72 vs. 2.02 ± 0.79 vs. 2.31 ± 0.72 mg·cm(2)·min(-1), P = 0.19) nor was SO (10.47 ± 2.54 vs. 10.04 ± 2.97 vs. 9.87 ± 3.44 min P = 0.82). Bilateral SR (2.14 ± 0.72 vs. 2.16 ± 0.71 mg·cm(2)·min(-1), P = 0.56) and SO (10.47 ± 2.54 vs. 10.83 ± 2.48 min, P = 0.09) were similar and differences were ≤ 1 SD of day-to-day differences for a single forearm. Analytical imprecision (CV(a)), within (CV(i))-, and between (CV(g))-subjects' coefficient of variation for local SR were 2.4%, 22.3%, and 56.4%, respectively, and were 0%, 9.6%, and 41%, respectively, for SO. We conclude: 1) technologically, sweat capsules contribute negligibly to sweat measurement variation; 2) bilateral measures of SR and SO appear interchangeable; 3) when studying potential factors affecting sweating, changes in SO afford a more favorable signal-to-noise ratio vs. changes in SR. These findings provide a quantitative basis for study design and optimization of power/sample size analysis in the evaluation of thermoregulatory sweating.