Loading…

The gait of patients with one resurfacing and one replacement hip: a single blinded controlled study

Purposes Post arthroplasty gait analysis has up till now been performed on subjects walking slowly on flat ground rather than challenging them at faster speeds or walking uphill. We therefore asked: (1) Is there a measurable difference in the performance of hip resurfacing arthroplasty (HRA) and tot...

Full description

Saved in:
Bibliographic Details
Published in:International orthopaedics 2013-05, Vol.37 (5), p.795-801
Main Authors: Aqil, Adeel, Drabu, Roshan, Bergmann, Jeroen H., Masjedi, Milad, Manning, Victoria, Andrews, Barry, Muirhead-Allwood, Sarah K., Cobb, Justin P.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purposes Post arthroplasty gait analysis has up till now been performed on subjects walking slowly on flat ground rather than challenging them at faster speeds or walking uphill. We therefore asked: (1) Is there a measurable difference in the performance of hip resurfacing arthroplasty (HRA) and total hip arthroplasty (THA) limbs at patients’ self-determined fastest walking speeds and steepest inclines? and (2) Is there a relationship between the observed differences between the gait of HRA and THA implanted limbs and patient walking speeds and inclines. Methods In an ethically approved study we recruited patients with bilateral hip arthroplasties: one HRA and one THA. Nine subjects were assessed using an instrumented treadmill at a range of speeds and inclines by a blinded observer. The ground reaction forces of subjects were recorded and an age, sex and BMI matched control group was used for comparison. Results Increasing walking speed correlated strongly with between leg differences in weight acceptance ( r  = 0.9, p  = 0.000) and push-off force ( r  = 0.79, p  = 0.002). HRA implanted limbs accepted significantly more weight at top walking speeds (1208 N ± 320 versus 1279 N ± 370, p  = 0.026) and pushed off with greater force when walking uphill (818 N ± 163 versus 855 ± 166, p  = 0.012). HRA limbs more closely approximated to the gait of the normal control group. Conclusions Arthroplasty implants do have an impact on the gait characteristics of patients. Differences in gait are more likely to be evident when assessment is made at fast speeds and walking uphill. This study suggests that HRA may enable a more normal gait.
ISSN:0341-2695
1432-5195
DOI:10.1007/s00264-013-1819-3