Iterative CT reconstruction in abdominal low-dose CT used for hybrid SPECT-CT applications: effect on image quality, image noise, detectability, and reader’s confidence
Background Iterative computed tomography (CT) image reconstruction shows high potential for the preservation of image quality in diagnostic CT while reducing patients’ exposure; it has become available for low-dose CT (LD-CT) in high-end hybrid imaging systems (e.g. single-photon emission computed t...
Saved in:
Published in: | Acta radiologica open 2019-06, Vol.8 (6), p.2058460119856266-2058460119856266 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background
Iterative computed tomography (CT) image reconstruction shows high potential for the preservation of image quality in diagnostic CT while reducing patients’ exposure; it has become available for low-dose CT (LD-CT) in high-end hybrid imaging systems (e.g. single-photon emission computed tomography [SPECT]-CT).
Purpose
To examine the effect of an iterative CT reconstruction algorithm on image quality, image noise, detectability, and the reader’s confidence for LD-CT data by a subjective assessment.
Material and Methods
The LD-CT data were validated for 40 patients examined by an abdominal hybrid SPECT-CT (U = 120 kV, I = 40 mA, pitch = 1.375). LD-CT was reconstructed using either filtered back projection (FBP) or an iterative image reconstruction algorithm (Adaptive Statistical Iterative Reconstruction [ASIR]®) with different parameters (ASIR levels 50% and 100%). The data were validated by two independent blinded readers using a scoring system for image quality, image noise, detectability, and reader confidence, for a predefined set of 16 anatomic substructures.
Results
The image quality was significantly improved by iterative reconstruction of the LD-CT data compared with FBP (P ≤ 0.0001). While detectability increased in only 2/16 structures (P ≤ 0.03), the reader’s confidence increased significantly due to iterative reconstruction (P ≤ 0.002). Meanwhile, at the ASIR level of 100%, the detectability in bone structure was highly reduced (P = 0.003).
Conclusion
An ASIR level of 50% represents a good compromise in abdominal LD-CT image reconstruction. The specific ASIR level improved image quality (reduced image noise) and reader confidence, while preserving detectability of bone structure. |
---|---|