A New Solid-Phase Extraction Method for Determination of Pantoprazole in Human Plasma Using High-Performance Liquid Chromatography
A new simple, selective and accurate high-performance liquid chromatographic (HPLC) method utilising solid-phase extraction for the determination of pantoprazole in human plasma samples has been developed. The purpose of this paper was developing a new HPLC method suitable for the determination of p...
Saved in:
Published in: | Open access Macedonian journal of medical sciences 2019-06, Vol.7 (11), p.1757-1761 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A new simple, selective and accurate high-performance liquid chromatographic (HPLC) method utilising solid-phase extraction for the determination of pantoprazole in human plasma samples has been developed.
The purpose of this paper was developing a new HPLC method suitable for the determination of pantoprazole in plasma samples, which enables simple and rapid isolation and concentration of the analysed drug.
The chromatographic separation was accomplished on a LiChroCart LiChrospher 60 RP select B column using a mobile phase composed of 0.2 % (V/V) water solution of triethylamine (pH 7) and acetonitrile (58:42, V/V) followed by UV detection was at 280 nm. The solid-phase extraction method using LiChrolut RP-18 (200 mg, 3 ml) was applied to the obtained good separation of investigated drug from endogenous plasma components. Best results were achieved when plasma samples were buffered with 0.1 mol/L KH2PO4 (pH 9) before extraction, eluted and reconstituted with acetonitrile and 0.001 mol/L NaOH after extraction, respectively.
The standard calibration curves showed good linearity within the range of 25.0-4000.0 ng/mL with a correlation coefficient greater than 0.996. Retention times of pantoprazole and internal standard, lansoprazole was 4.1 and 6.0 min respectively. The limit of quantification was 25.0 ng/mL. For intra- and inter-day precision relative standard deviations ranged from 4.2 to 9.3%. The relative errors for stability investigations were ranged from 0.12 to -10.5%.
This method has good precision and accuracy and was successfully applied to the pharmacokinetic and bioequivalence study of 40 mg pantoprazole in healthy volunteers. |
---|---|
ISSN: | 1857-9655 1857-9655 |
DOI: | 10.3889/oamjms.2019.237 |