Loading…

A New Solid-Phase Extraction Method for Determination of Pantoprazole in Human Plasma Using High-Performance Liquid Chromatography

A new simple, selective and accurate high-performance liquid chromatographic (HPLC) method utilising solid-phase extraction for the determination of pantoprazole in human plasma samples has been developed. The purpose of this paper was developing a new HPLC method suitable for the determination of p...

Full description

Saved in:
Bibliographic Details
Published in:Open access Macedonian journal of medical sciences 2019-06, Vol.7 (11), p.1757-1761
Main Authors: Zendelovska, Dragica, Atanasovska, Emilija, Gjorgjievska, Kalina, Pavlovska, Kristina, Jakjovski, Krume, Zafirov, Dimce, Trojacanec, Jasmina
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new simple, selective and accurate high-performance liquid chromatographic (HPLC) method utilising solid-phase extraction for the determination of pantoprazole in human plasma samples has been developed. The purpose of this paper was developing a new HPLC method suitable for the determination of pantoprazole in plasma samples, which enables simple and rapid isolation and concentration of the analysed drug. The chromatographic separation was accomplished on a LiChroCart LiChrospher 60 RP select B column using a mobile phase composed of 0.2 % (V/V) water solution of triethylamine (pH 7) and acetonitrile (58:42, V/V) followed by UV detection was at 280 nm. The solid-phase extraction method using LiChrolut RP-18 (200 mg, 3 ml) was applied to the obtained good separation of investigated drug from endogenous plasma components. Best results were achieved when plasma samples were buffered with 0.1 mol/L KH2PO4 (pH 9) before extraction, eluted and reconstituted with acetonitrile and 0.001 mol/L NaOH after extraction, respectively. The standard calibration curves showed good linearity within the range of 25.0-4000.0 ng/mL with a correlation coefficient greater than 0.996. Retention times of pantoprazole and internal standard, lansoprazole was 4.1 and 6.0 min respectively. The limit of quantification was 25.0 ng/mL. For intra- and inter-day precision relative standard deviations ranged from 4.2 to 9.3%. The relative errors for stability investigations were ranged from 0.12 to -10.5%. This method has good precision and accuracy and was successfully applied to the pharmacokinetic and bioequivalence study of 40 mg pantoprazole in healthy volunteers.
ISSN:1857-9655
1857-9655
DOI:10.3889/oamjms.2019.237